Kindly browse your automation parts that you are looking for on this page! MISEL does offer automation parts from other brands as well such as SIKO, WAGO, AUTONICS, FUJI, and many more. In addition, we also offer support services such as product introduction, installation to our customers who purchase automation parts.
To get further details especially about price and availability status of products, don’t be hesitate to contact our marketing team. We are always available to assist you to get your automation needs. Thank You!

EM AT08 Thermocouple module

Categories: Temperature Module

Description

8-channel thermocouple module, resolution 16 bits

Model and Article Information

  • Model Number: EM AT08
  • Article Number: E 288-3AT08-0AA1
  • Description: 8-channel thermocouple module with 16-bit resolution for accurate and reliable temperature measurements.

Physical and Power Specifications

  • Dimensions (WxHxD): 47 mm × 100 mm × 81 mm
  • Power Consumption: 1.5 W
  • Current Consumption:
    • SM bus: 50 mA
    • 24V DC: 40 mA

Analog Input Specifications

  • Number of Inputs: 8 channels for thermocouple connections
  • Input Type: Thermocouple (TC)
  • Input Range:
    • Types Supported: E, J, K, N, R, S, T (standard thermocouple types)
    • Voltage Range: ±80 mV (standard voltage range for thermocouple inputs)
    • Data Word Format: Voltage range from -27648 to +27648, providing a wide data range for voltage measurement.

Measuring Principle

  • Measuring Principle: Sigma-Delta (provides high accuracy and stable data conversion from analog to digital)

Resolution

  • Temperature Resolution: 0.1°C / 0.1°F
  • Voltage Resolution: 15 bits + symbol bits (providing high precision in voltage measurement)

Max Voltage Resistance

  • Max. Voltage Resistance: ±35V (ensures the module can withstand voltage spikes without damage)

Isolation and Protection

  • Isolation:
    • Field side and logic side: 500V AC
    • Field side and 24V DC side: 500V AC
    • 24V DC side and logic side: 500V AC
  • Channel-to-Channel Isolation: Supported (each channel is isolated to prevent cross-talk and improve noise immunity)
  • Common Mode Rejection: >120 dB at 120V AC (excellent protection against common-mode noise from electrical interference)
  • Repeatability: ±0.05% FS (Full Scale) for consistent and reliable temperature measurements

Cold Junction Compensation

  • Cold End Temperature Error: ±1.5°C (important for accurate thermocouple readings, as it compensates for the cold junction where the thermocouple leads connect)

Cable and Sensor Specifications

  • Cable Loop Resistance (Max): 100Ω (ensures signal integrity and minimizes measurement errors in the wiring)
  • Cable Length: Up to 100 meters with shielded twisted pair cable (ideal for long-distance applications without significant signal loss or noise interference)

Diagnostic Features

  • Diagnosis Capabilities:
    • Overflow/underflow detection
    • Circuit break detection
    • 24V DC low voltage detection (ensures reliable power supply)