Description
Micro PLC designed to support data collection and Machine to Machine communication.
We also provide other products such as :
- Omron Limit Switch
- Omron Power Supply
- Omron Level Switches
Specification
General Specifications
Item | AC power supply | DC power supply | |
---|---|---|---|
Model | CP2E-[][][]D[]-A | CP2E-[][][]D[]-D | |
Enclosure | Mounted in a panel | ||
Dimensions (H × D × W) | CPU Unit with 14 or 20 I/O points (CP2E-[]14/20D[]-[]): 90mm *1 ×80mm *2 × 86mm CPU Unit with 30 I/O points (CP2E-[]30D[]-[]): 90mm *1 × 80mm *2 × 130mm CPU Unit with 40 I/O points (CP2E-[]40D[]-[]): 90mm *1 × 80mm *2 × 150mm CPU Unit with 60 I/O points (CP2E-[]60D[]-[]): 90mm *1 × 80mm *2 × 195mm |
||
Weight | CPU Unit with 14 I/O points (CP2E-[]14D[]-[]): 335g max. CPU Unit with 20 I/O points (CP2E-[]20D[]-[]): 340g max. CPU Unit with 30 I/O points (CP2E-[]30D[]-[]): 580g max. CPU Unit with 40 I/O points (CP2E-[]40D[]-[]): 640g max. CPU Unit with 60 I/O points (CP2E-[]60D[]-[]): 780g max. |
||
Electrical specifications |
Supply voltage | 100 to 240 VAC 50/60 Hz | 24 VDC |
Operating voltage range |
85 to 264 VAC | 20.4 to 26.4 VDC | |
Power consumption |
15 VA/100 VAC max. 25 VA/240 VAC max. (CP2E-[]14/20D[]-A) |
13W max. (CP2E-[]14/20D[]-D) | |
50 VA/100 VAC max. 70 VA/240 VAC max. (CP2E-[]30/40/60D[]-A) |
20W max. (CP2E-[]30/40/60D[]-D) *4 | ||
Inrush current | 120 VAC, 20 A for 8 ms max. for cold start at room temperature 240 VAC, 40 A for 8 ms max. for cold start at room temperature |
24 VDC, 30A for 20 ms max. for cold start at room temperature |
|
External power supply *3 |
Not provided. (CP2E-[]14/20D[]-A) 24 VDC, 300 mA (CP2E-[]30/40/ 60D[]-A) |
Not provided. | |
Insulation resistance |
20 MΩ min. (at 500 VDC) between the external AC terminals and GR terminals |
Not csolated between primary and secondary DC power supplies |
|
Dielectric strength | 2,300 VAC 50/60Hz for 1 min between AC external and GR terminals Leakage current: 5 mA max. |
Not csolated between primary and secondary DC power supplies |
|
Power interrupt time |
10 ms min. | 2 ms min. | |
Application environment |
Ambient operating temperature |
-20 to 60°C | |
Ambient humidity | 10% to 90% | ||
Atmosphere | No corrosive gas. | ||
Ambient storage temperature |
-20 to 75°C (excluding battery) | ||
Altitude | 2,000 m max. | ||
Pollution degree | 2 or less: Conforms to IEC61010-2-201. | ||
Noise resistance | 2 kV on power supply line (Conforms to IEC61000-4-4.) | ||
Overvoltage category |
Category II: Conforms to IEC61010-2-201. | ||
EMC immunity level |
Zone B | ||
Vibration resistance |
Conforms to IEC60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
||
Shock resistance | Conforms to IEC60068-2-27. 147 m/s2, 3 times in X, Y, and Z directions |
||
Terminal block | Fixed (not removable) | ||
Terminal screw size | M3 | ||
Applicable standards | Conforms to EC Directives, KC, UL and EAC. | ||
Grounding method | Ground to 100Ω or less. |
*2. Excluding cables.
*3. Use the external power supply to power input devices. Do not use it to drive output devices.
*4. This is the rated value for the maximum system configuration. Use the following formula to calculate power
consumption for CPU Units with DC power.
Formula: DC power consumption = (5V current consumption × 5 V/70% (internal power efficiency) + 24V current
consumption) × 1.1 (current fluctuation factor)
The above calculation results show that a DC power supply with a greater capacity is required.
Note: 1. The Expansion I/O Units and Expansion Units work under the same conditions as the CPU Units unless otherwise
specified.
Performance Specifications
Item | CP2E-E[][]D[]-[] | CP2E-S[][]D[]-[] | CP2E-N[][]D[]-[] | ||
---|---|---|---|---|---|
Program capacity | 4K steps | 8K steps | 10K steps | ||
FB capacity | 4K steps | 8K steps | 10K steps | ||
Control method | Stored program method | ||||
I/O control method | Cyclic scan with immediate refreshing | ||||
Program language | Ladder diagram | ||||
Function blocks | Maximum number of function block definitions: 64 Maximum number of instances: 128 Languages usable in function block definitions: Ladder diagrams, structured text (ST) |
||||
Instructions | Approximately 220 | ||||
Proc- essing speed |
Overhead processing time | 0.1 ms | 0.15 ms | 0.2 ms | |
Instruction execution times | LD 0.23 μs MOV 1.76 μs |
||||
Number of CP1W-series Expansion I/O Units and Expansion Units connected |
CP2E-[]14/20D[]-[]: None CP2E-[]30/40/60D[]-[]: 3 units |
||||
Maximum number of I/O points | CP2E-[]14D[]-[]: 14 CP2E-[]20D[]-[]: 20 CP2E-[]30D[]-[]: 150 (30 built in, 40 × 3 expansion) CP2E-[]40D[]-[]: 160 (40 built in, 40 × 3 expansion) CP2E-[]60D[]-[]: 180 (60 built in, 40 × 3 expansion) |
||||
Built-in input function |
High- speed counters |
High-speed counter mode/ maximum frequency |
Incremental Pulse Inputs 100 kHz: 2 counters 10 kHz: 4 counters Up/Down Inputs 100 kHz: 1 counter 10 kHz: 1 counter Pulse + Direction Inputs 100 kHz: 2 counters Differential Phase Inputs (4x) 50 kHz: 1 counter 5 kHz: 1 counter |
N14/20D[]-[]
Incremental Pulse Inputs 100 kHz: 2 counters 10 kHz: 4 counters Up/Down Inputs 100 kHz: 1 counter 10 kHz: 1 counter Pulse + Direction Inputs 100 kHz: 2 counters Differential Phase Inputs (4x) 50 kHz: 1 counter 5 kHz: 1 counterN30/40/60D[]-[] Incremental Pulse Inputs 100 kHz: 3 counters 10 kHz: 3 counters Up/Down Inputs 100 kHz: 2 counters, Pulse + Direction Inputs 100 kHz: 2 counters Differential Phase Inputs (4x) 50 kHz: 2 counters |
|
Counting mode | • Linear mode • Ring mode |
||||
Count value | 32 bits | ||||
Counter reset modes |
• Phase Z and software reset (excluding increment pulse input) • Software reset |
||||
Control method | • Target matching • Range comparison |
||||
Input interrupts | 6 inputs | 8 inputs (6 inputs only for 14 I/O points) |
|||
Interrupt input pulse width: 50 µs min. | |||||
Quick-response inputs | 6 inputs | 8 inputs (6 inputs only for 14 I/O points) |
|||
Input pulse width: 50 µs min. | |||||
Normal input |
Input constants | Delays can be set in the PLC setup (0 to 32 ms, default: 8 ms). Set values: 0, 1, 2, 4, 8, 16, or 32 ms |
|||
Built-in output function |
Pulse outputs (Models with transistor outputs only) |
Pulse output | Pulse output function not included |
Pulse + Direction Mode | |
Frequency | 1 Hz to 100kHz: 2 outputs |
N14/20D[]-[]
1 Hz to 100kHz: 2 outputs N30/40/60D[]-[] 1 Hz to 100kHz: 4 outputs |
|||
Output mode | • Continuous mode (for speed control) • Independent mode (for position control) |
||||
Number of output pulses |
• Relative coordinates: 0000 0000 to 7FFF FFFF hex (0 to 2147483647) • Absolute coordinates: 8000 0000 to 7FFF FFFF hex (-2147483647 to 2147483647) |
||||
Acceleration/ deceleration curves |
Trapezoidal acceleration and deceleration (Cannot perform S-curve acceleration and deceleration). |
||||
Changing SVs during instruction execution |
Only target position can be changed. | ||||
Origin searches | Included | ||||
Linear interpolation |
None | N14/20D[]-[]
2 axes max. N30/40/60D[]-[] 4 axes max. |
|||
PWM output (transistor outputs models only) |
Frequency | PWM output function not included |
2.0 to 6,553.5 Hz (in increments of 0.1 Hz) with 1 output or 2 Hz to 32,000 Hz (in increments of 1 Hz) with 1 output |
||
Duty factor | 0.0% to 100.0% (in increments of 0.1%) Accuracy: +1%/-0% at 2 Hz to 10,000 Hz and +5%/-0% at 10,000 Hz to 32,000 kHz |
||||
Output mode | Continuous Mode | ||||
Com- muni- cations |
Peripheral USB port | Conforming to USB 2.0 B-type conntor | None | ||
Transmission distance |
5 m max. | ||||
Built-in RS232C port | Interface: Conforming to EIA RS-232C | None | |||
Transmission distance |
15 m max. | ||||
Communications method |
Half duplex | ||||
Synchronization | Start-stop | ||||
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps |
||||
Supported protocol |
• Host Link • 1:N NT Link • No-protocol mode • Serial PLC Links (master, slave) • Modbus-RTU Easy Master • Modbus-RTU Slave |
||||
Built-in RS485 port (not isolated) |
None | Interface: Conforming to EIA RS-485 |
None | ||
Transmission distance |
50 m max. | ||||
Communications method |
Half duplex | ||||
Synchronization | Start-stop | ||||
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps |
||||
Supported protocol |
• Host Link • 1:N NT Link • No-protocol mode • Serial PLC Links (master, slave) • Modbus-RTU Easy Master • Modbus-RTU Slave |
||||
Serial Option port |
Number of Option Boards |
None | N14/20D[]-[]
1 Option Board N30/40/60D[]-[] 2 Option Boards |
||
Number of serial communications |
N14/20D[]-[]
2 ports max. N30/40/60D[]-[] 3 ports max. |
||||
Communications method |
Depends on Option Board | ||||
Synchronization | Depends on Option Board | ||||
Baud rate | 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps |
||||
Mountable Option Boards |
Serial Communication Option Board with one port • One RS-232C port: CP1W-CIF01 (Start-stop) • One RS-422A/485 port (not isolated): CP1W-CIF11 (Start-stop) • One RS-422A/485 port (isolated): CP1W-CIF12-V1 (Start-stop) Serial Communication Option Board with two ports *1 • Two RS-232C ports: CP2W-CIFD1 (Start-stop) • One RS-232C port and one RS- 485 port (isolated): CP2W-CIFD2 (Start-stop) • Two RS-485 ports (isolated): CP2W-CIFD3 (Start-stop) Analog Option Board *2 CP1W-MAB221/ADB21/DAB21V *1. CP2W-CIFD[] can only be mounted on option slot 1. *2. Maximum one Analog Option Board can be mounted on an N[][]-type CPU Unit. |
||||
Compatible protocols |
• Host Link* • 1:N NT Link* • No-protocol mode • Serial PLC Links (master, slave) • Modbus-RTU Easy Master • Modbus-RTU Slave * PORT1 (EX) is not supported. |
||||
Ethernet | Physical layer | None | 100/10BASE-TX (Auto-MDIX) | ||
Media access methiod |
CSMA/CD | ||||
Modulation | Baseband | ||||
Baud rate | 100BASE-TX: 100Mbit/s 10BASE-T: 10Mbit/s • Half/full auto-negotiation for each port • Link speed auto-sensing for each port |
||||
Transmission media |
100BASE-TX • Unshielded twisted-pair (UDP) cable Categories: 5, 5e • Shielded twisted-pair (STP) cable Categories: 100Ω at 5, 5e 10BASE-T • Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e • Shielded twisted-pair (STP) cable Categories: 100Ω at 3, 4, 5, 5e |
||||
Transmission distance |
100 m (distance between switch and node) |
||||
Protocol | TCP, UDP, APR, ICMP (ping only), SNTP, DNS |
||||
Applications | FINS, Socket, SNTP, DNS (Client) |
||||
Number of Ethernet ports |
N14/20: 1 port N30/40/60: 2 ports |
||||
Ethernet switch | Layer 2 switch * N14/20 is not supported. |
||||
Number of tasks | 17 • 1 cyclic task • 16 interrupt tasks Scheduled interrupt task: Interrupt task 1 (fixed) Built-in input interrupt task: Interrupt task 2 to 9 (IN8 and IN9 can only be used in N20/30/40/60 CPU Units) High-speed counter interrupt task: Interrupt task 1 to 16 |
||||
Maximum subroutine number | 128 | ||||
Maximum jump number | 128 | ||||
Scheduled interrupt tasks | 1 interrupt task | ||||
Battery service life *With CP2W-BAT02 Battery (optional) |
Battery cannot be mounted. |
CP2W-BAT02 can be mounted. Maximum battery service life: 5 years Guaranteed Lifetime Ambient temperature is 60°C: 13,000 hours (approx. 1.5 years) Ambient temperature is 25°C: 43,000 hours (approx. 5 years) |
|||
Clock | None | Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature: 60°C), -2.0 min to +2.0 min (ambient temperature: 25°C), -2.5 min to +1.5 min (ambient temperature: -20°C) |
|||
Memory backup |
Built-in Flash Memory | Ladder programs and parameters are automatically saved to built-in Flash Memory. A section of the Data Memory Area can be saved to the built-in Flash Memory. |
|||
Built-in non-volatile memory | Data Memory Area (D), Holding Area (H), Counter Area (C) and Auxiliary Area (A) are automatically saved to the built-in non-volatile memory. |
||||
CIO Area |
Input Bits | 1,600 bits (100 words): CIO 0.00 to CIO 99.15 (CIO 00 to CIO 99) | |||
Output Bits | 1,600 bits (100 words): CIO 100.00 to CIO 199.15 (CIO 100 to CIO 199) | ||||
Serial PLC Link Words | 1,440 bits (90 words): CIO 200.00 to CIO 289.15 (CIO 200 to CIO 289) | ||||
Work Area (W) | 2,048 bits (128 words): W0.00 to W127.15 (W0 to W127) | ||||
Holding Area (H) | 2,048 bits (128 words): H0.00 to H127.15 (H0 to 127) Words H512 to H1535: These words can be used only for function blocks. |
||||
Auxiliary Area (A) | Read-only: 7,168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/write: 8,192 bits (512 words): A448.00 to A959.15 (A448 to A959) |
||||
Temporary Area (TR) | 16 bits: TR0 to TR15 | ||||
Timer Area (T) | 256 timer numbers (T0 to T255 (separate from counters)) Words T256 to T511: These words can be used only for function blocks. |
||||
Counter Area (C) | 256 counter numbers (C0 to C255 (separate from timers)) Words C256 to C511: These words can be used only for function blocks. |
||||
Data Memory Area (D) | 4 K words: D0 to D4095 DM backup: 1,500 words (D0 to D1499) |
8 K words: D0 to D8191 DM backup: 7,000 words (D0 to D6999) |
16 K words: D0 to D16383 DM backup: 15,000 words (D0 to D14999) |
||
Index Registers (IR) | 16 registers: IR0 to IR15 | ||||
Data Registers (DR) | 16 registers: DR0 to DR15 | ||||
Operating modes | PROGRAM Mode: Program execution is stopped. Preparations can be executed prior to program execution in this mode. MONITOR Mode: Programs are executed. Some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode. RUN Mode: Programs are executed. This is the normal operating mode. |
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.
Feel free to contact us for more information :
Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
[email protected]
WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995
Reviews
There are no reviews yet.