• Reduces wiring work by 60% when combined with the P2RF-[]-PU Push-In Plus Socket (according to actual OMRON measurements).
• Lockable test button models available.
• Built-in mechanical operation indicator.
• Provided with nameplate.
• AC type is equipped with a coil-disconnection self-diagnostic function (LED type).
• High switching power (1-pole: 10 A)
Specification
Coil Ratings
Rated voltage |
Rated current* |
Coil
resistance |
Coil inductance (H)
(ref. value) |
Must
operate
voltage |
Must
release
voltage |
Max.
voltage |
Power
consumption
(approx.) |
50 Hz |
60 Hz |
Armature
OFF |
Armature
ON |
% of rated voltage |
AC |
24 V |
43.5 mA |
37.4 mA |
253 Ω |
0.81 |
1.55 |
80% max. |
30% max. |
110% |
0.9 VA at 60 Hz |
48 V |
21.8 mA |
18.8 mA |
1,040 Ω |
3.12 |
6.17 |
110 V |
9.5 mA |
8.2 mA |
5,566 Ω |
13.33 |
26.83 |
120 V |
8.6 mA |
7.5 mA |
7,286 Ω |
16.13 |
32.46 |
230 V |
4.4 mA |
3.8 mA |
27,172 Ω |
72.68 |
143.9 |
240 V |
4.2 mA |
3.7 mA |
27,800 Ω |
90.58 |
182.34 |
Rated voltage |
Rated current* |
Coil
resistance |
Coil inductance (H)
(ref. value) |
Must
operate
voltage |
Must
release
voltage |
Max.
voltage |
Power
consumption
(approx.) |
Armature
OFF |
Armature
ON |
% of rated voltage |
DC |
6 V |
87.0 mA |
69 Ω |
0.25 |
0.48 |
70% max. |
15% min. |
110% |
0.53 W |
12 V |
43.2 mA |
278 Ω |
0.98 |
2.35 |
24 V |
21.6 mA |
1,113 Ω |
3.6 |
8.25 |
48 V |
11.4 mA |
4,220 Ω |
15.2 |
29.82 |
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of
+15%/-20% for the AC rated current and ±10% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.
Contact Ratings
Number of poles |
1 pole |
2 poles |
Load |
Resistive load
(cosΦ = 1) |
Inductive load
(cosΦ = 0.4; L/R = 7 ms) |
Resistive load
(cosΦ = 1) |
Inductive load
(cosΦ = 0.4; L/R = 7 ms) |
Rated load |
10 A at 250 VAC;
10 A at 30 VDC |
7.5 A at 250 VAC;
5 A at 30 VDC |
5 A at 250 VAC;
5 A at 30 VDC |
2 A at 250 VAC;
3 A at 30 VDC |
Rated carry current |
10 A |
5 A |
Max. switching voltage |
440 VAC, 125 VDC |
380 VAC, 125 VDC |
Max. switching current |
10 A |
5 A |
Max. switching power |
2,500 VA, 300 W |
1,875 VA, 150 W |
1,250 VA, 150 W |
500 VA, 90 W |
Failure rate (reference value) * |
100 mA at 5 VDC |
10 mA at 5 VDC |
Note: P level: λ60 = 0.1 x 10-6/operation
*This value was measured at a switching frequency of 120 operations per minute.
Characteristics
Item |
1 pole |
2 poles |
Contact configration |
SPDT |
Contact structure |
Single |
Contact resistance |
100 mΩ max. |
Operate (set) time |
15 ms max. |
Release (reset) time |
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.) |
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.) |
Max. operating
frequency |
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load) |
Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
Dielectric strength * |
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity |
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity |
Vibration resistance |
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Shock resistance |
Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized |
Endurance |
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type) |
Ambient temperature |
Operating: -40°C to 70°C (with no icing or condensation) |
Ambient humidity |
Operating: 5% to 85% |
Weight |
Approx. 20 g |
Note: Values in the above table are the initial values.
*These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.
Approved Standards
UL 508 (File No. E41643)
Model |
Contact form |
Coil ratings |
Contact ratings |
Operations |
G2R-1-S (S) |
SPDT |
5 to 110 VDC
6 to 240 VAC |
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use) |
100 × 103 |
TV-3 (NO contact only) |
25 × 103 |
G2R-2-S (S) |
DPDT |
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use) |
100 × 103 |
TV-3 (NO contact only) |
25 × 103 |
CSA 22.2 No.0, No.14 (File No. LR31928)
Model |
Contact form |
Coil ratings |
Contact ratings |
Operations |
G2R-1-S (S) |
SPDT |
5 to 110 VDC
6 to 240 VAC |
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use) |
100 × 103 |
TV-3 (NO contact only) |
25 × 103 |
G2R-2-S (S) |
DPDT |
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use) |
100 × 103 |
TV-3 (NO contact only) |
25 × 103 |
IEC/VDE (Certificate No. 40015012 EN 61810-1)
Contact form |
Coil ratings |
Contact ratings |
Operations |
1 pole |
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC |
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms) |
100 × 103 |
2 poles |
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC |
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms) |
100 × 103 |
LR
Number of poles |
Coil ratings |
Contact ratings |
Operations |
1 pole |
5 to 110 VDC
6 to 240 VDC |
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms) |
100 × 103 |
2 poles |
5 to 110 VDC
6 to 240 VDC |
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms) |
100 × 103 |
Accessories (Order Separately)
Socket Characteristics
Model |
Continuous
carry
current |
Dielectric strength |
Insulation
resistance* |
Remarks |
P2RF-05-PU |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between coil and contact terminals: 4,000 VAC for 1 min |
P2RF-08-PU |
6 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
P2RFZ-05(-E) |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between coil and contact terminals: 4,000 VAC for 1 min |
P2RFZ-08(-E) |
6 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
P2RF-05 |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between coil and contact terminals: 4,000 VAC for 1 min |
P2RF-08 |
5 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
P2R-05P |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between coil and contact terminals: 4,000 VAC for 1 min |
P2R-08P |
5 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
P2R-057P |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between coil and contact terminals: 5,000 VAC for 1 min |
P2R-087P |
5 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between coil and contact terminals: 5,000 VAC for 1 min |
P2R-05A |
10 A |
Between contact terminals of same polarity: 1,000 VAC for
1 min |
1,000 MΩ min. |
|
Between ground terminals: 1,500 VAC for 1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
P2R-08A |
5 A |
Between contact terminals of different polarity: 3,000 VAC
for 1 min |
1,000 MΩ min. |
|
Between contact terminals of same polarity: 1,000 VAC for
1 min |
Between ground terminals: 1,500 VAC for 1 min |
Between coil and contact terminals: 4,000 VAC for 1 min |
* The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those used for
measuring the dielectric strength.
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.
Feel free to contact us for more information :
Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
[email protected]
WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995