Description
Three external connection methods: Surface mounting with 8- or 11-pin socket, flush mounting with 8- or 11-pin socket, top screw tightening terminal
• Handles a wide range of applications through eight operating modes.
• With H3BA-N8H models, the output type can be switched between time-limit DPDT and time-limit SPDT + instantaneous SPDT using a selector.
• Setting rings (order separately) to enable consistent settings and to limit the setting range.
• Panel Covers (order separately) to enable various panel designs.
• CE marking.
UL, CSA and CCC certification, conforms to LR
Specification
General
Item | H3BA-N | H3BA-N8H |
---|---|---|
Operating mode | A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot |
A: ON-delay H: ON-delay with instantaneous output contact |
Pin type | 11-pin | 8-pin |
Input type | No-voltage input | — |
Output type | DPDT (time-limit) | SPDT (time-limit) and switchable SPDT (time-limit <—> instantaneous) |
Mounting method | DIN track mounting, surface mounting, and flush mounting | |
Approved standards | UL508, CSA C22.2 No.14, LR, CCC: GB/T 14048.5 * Conforms to EN61812-1 (Pollution degree 2/Overvoltage category III) |
|
EMC | (EMI) EN61812-1 Radiated Emissions: EN 55011 class A Emission AC Mains: EN 55011 class A (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency EN 61000-4-3: 10 V/m (80 MHz to 1 GHz AM modulation) Electromagnetic Field Immunity: 3 V/m (1.4 GHz to 2 GHz AM modulation), 1 V/m (2 GHz to 2.7 GHz AM modulation), 10 V/m (900 MHz Pulse modulation) Conducted disturbances: EN 61000-4-6: 10 V (0.15 MHz to 80 MHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 2 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode Voltage dips: EN 61000-4-11 Voltage interruptions: EN 61000-4-11 |
* CCC certification requirements
Recommended fuse | 0216005 (250 VAC, 5 A) manufactured by Littelfuse |
---|---|
Rated operating voltage Ue Rated operating current Ie |
AC-15: Ue: 250 VAC, Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 1.5 A |
Rated insulation voltage | 250 V |
Rated impulse withstand voltage (altitude: 2,000 m max.) |
4 kV (at 240 VAC) |
Conditional short-circuit current | 1,000 A |
Time Ranges
Time unit | sec | × 10 s | min | × 10 m | hrs | × 10 h | |
---|---|---|---|---|---|---|---|
Full scale setting | |||||||
1.2 | Set time | 0.05 to 1.2 | 1.2 to 12 | 0.12 to 1.2 | 1.2 to 12 | 0.12 to 1.2 | 1.2 to 12 |
3 | 0.3 to 3 | 3 to 30 | 0.3 to 3 | 3 to 30 | 0.3 to 3 | 3 to 30 | |
12 | 1.2 to 12 | 12 to 120 | 1.2 to 12 | 12 to 120 | 1.2 to 12 | 12 to 120 | |
30 | 3 to 30 | 30 to 300 | 3 to 30 | 30 to 300 | 3 to 30 | 30 to 300 |
Ratings
Item | H3BA-N | H3BA-N8H |
---|---|---|
Rated supply voltage *1 *2 | 110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC | |
Operating voltage range *3 | 85% to 110% of rated supply voltage | |
Power reset | Minimum power-opening time: 0.1 s | |
No-voltage input | ON impedance: 1 kΩ max. ON residual voltage: 1 V max. OFF impedance: 200 kΩ min. |
|
Power consumption | 110 VAC: Approx. 4.6 VA (1.5 W) 220 VAC: Approx. 7.6 VA (1.3 W) 24 VDC: Approx. 0.6 W |
110 VAC: Approx. 3.6 VA (1.6 W) 220 VAC: Approx. 7.8 VA (1.9 W) 24 VDC: Approx. 0.9 W |
Control outputs | Contact: 5 A at 250 VAC, resistance load (cosφ = 1) |
*2. Models other than 24-VDC H3BA-N models cause an inrush current. Pay careful attention when attempting to turn on
power to such models with non-contact output from a device such as a sensor.
*3. 90% or higher if the Timer is used continuously at a high ambient temperature.
Characteristics
Item | H3BA-N | H3BA-N8H |
---|---|---|
Accuracy of operating time | ±0.3% FS max. (±0.3%±10 ms in a range of 1.2 s) | |
Setting error | ±5% FS ±0.05 s max. | |
Reset time | Min. power-opening time: 0.1 s max. Min. pulse-input time: 50 ms |
|
Influence of voltage | ±0.5% FS max. (±0.5%±10 ms in a range of 1.2 s) | |
Influence of temperature | ±2% FS max. (±2%±10 ms in a range of 1.2 s) | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non- current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit 1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-N8H) |
|
Impulse withstand voltage | 1 kV (between power terminals) 2 kV (between current-carrying terminal and exposed non-current-carrying metal parts, 1.5 kV for 24-VDC models) |
|
Noise immunity | AC models: ±1.5 kV (between power terminals), and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) DC models: ±480 V (between power terminals), and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
|
Static immunity | Malfunction: 4 kV Destruction: 8 kV |
|
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions |
|
Shock resistance | Destruction: 1,000 m/s2 (approx. 100G) each in three directions Malfunction: 100 m/s2 (approx. 10G) each in three directions |
|
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
|
Ambient humidity | Operating: 35% to 85% | |
Life expectancy | Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) |
Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) |
Case color | Light gray (Munsell 5Y7/1) | |
Enclosure ratings | IEC: IP40 (panel surface) | |
Weight | Approx. 95 g |
in mode D (signal OFF-delay).
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.
Feel free to contact us for more information :
Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
[email protected]
WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995
Reviews
There are no reviews yet.