Description
• In addition to our standard type (MY), an abundant lineup of models including latching relays that retain contact operation status (MYK) and sealed relays suitable for environments where dust and corrosive gases are present (MYQ/MYH) are also available.
• Selection is possible to suit the application, such as models with operation indicators and models with latching levers (MY plug-in terminals).
• Wiring work can be shortened by as much as 60%* compared to conventional screw terminal sockets by combining with push-in plus terminal sockets (PYF-[]-PU) that feature light insertion force and strong pull-out strength to achieve less wiring work.
*When both push-in plus terminals and screw terminal sockets are combined with plug-in terminal types (according to actual OMRON measurements as of November 2015)
Specification
Terminal Type | Classification | Number of poles |
Contacts | Without operation indicator |
With operation indicator |
---|---|---|---|---|---|
Plug-in terminals | Standard models | 2 | Single | MY2 | MY2N |
4 | Single | MY4 | MY4N | ||
Bifurcated | MY4Z | MY4ZN | |||
Models with built-in diode for coil surge absorption (DC coil specification only) |
2 | Single | MY2-D | MY2N-D2 | |
4 | Single | MY4-D | MY4N-D2 | ||
Bifurcated | MY4Z-D | MY4ZN-D2 | |||
Models with built-in CR circuit for coil surge absorption (AC coil specification only) |
2 | Single | MY2-CR | MY2N-CR | |
4 | Single | MY4-CR | MY4N-CR | ||
Bifurcated | MY4Z-CR | MY4ZN-CR |
Item | Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) | Must operate voltage (V) |
Must release voltage (V) |
Maximum voltage (V) |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
Rated voltage (V) |
50 Hz | 60 Hz | Armature OFF |
Armature ON |
||||||
AC | 12 | 106.5 | 91 | 46 | 0.17 | 0.33 | 80% max. *1 |
30% min. *2 |
110% of rated voltage |
Approx. 0.9 to 1.3 (at 60 Hz) |
24 | 53.8 | 46 | 180 | 0.69 | 1.3 | |||||
100/110 | 11.7/12.9 | 10/11 | 3,750 | 14.54 | 24.6 | |||||
110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
220/240 | 4.8/5.3 | 4.2/4.6 | 18,790 | 83.5 | 136.4 | |||||
DC | 12 | 72.7 | 165 | 0.73 | 1.37 | 10% min. *2 |
Approx. 0.9 | |||
24 | 36.3 | 662 | 3.2 | 5.72 | ||||||
48 | 17.6 | 2,725 | 10.6 | 21.0 | ||||||
100/110 | 8.7/9.6 | 11,440 | 45.6 | 86.2 |
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value (at a coil temperature of 23°C).
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC.
To ensure release, use a value that is lower than the specified value.
Terminal Type | Classification | Number of poles |
Contacts | Without operation indicator |
With operation indicator |
---|---|---|---|---|---|
Plug-in terminals | Standard models | 2 | Bifurcated | MY2Z | MY2ZN |
Models with built-in diode for coil surge absorption (DC coil specification only) |
2 | Bifurcated | MY2Z-D | MY2ZN-D2 | |
3 | Single | MY3-D | MY3N-D2 | ||
Models with built-in CR circuit for coil surge absorption (AC coil specification only) |
2 | Bifurcated | MY2Z-CR | MY2ZN-CR |
Item | Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) | Must operate voltage (V) |
Must release voltage (V) |
Maximum voltage (V) |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
Rated voltage (V) |
50 Hz | 60 Hz | Armature OFF |
Armature ON |
||||||
AC | 12 | 106.5 | 91 | 46 | 0.17 | 0.33 | 80% max. *1 |
30% min. *2 |
110% of rated voltage |
Approx. 0.9 to 1.3 (at 60 Hz) |
24 | 53.8 | 46 | 180 | 0.69 | 1.3 | |||||
100/110 | 11.7/12.9 | 10/11 | 3,750 | 14.54 | 24.6 | |||||
110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
220/240 | 4.8/5.3 | 4.2/4.6 | 18,790 | 83.5 | 136.4 | |||||
DC | 12 | 75 | 160 | 0.73 | 1.37 | 10% min. *2 |
Approx. 0.9 | |||
24 | 36.9 | 650 | 3.2 | 5.72 | ||||||
48 | 18.5 | 2,600 | 10.6 | 21.0 | ||||||
100/110 | 9.1/10 | 11,000 | 45.6 | 86.2 |
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value.
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC.
To ensure release, use a value that is lower than the specified value.
Terminal Type | Classification | Number of poles | Contacts | With latching lever |
---|---|---|---|---|
Plug-in terminals | Standard models | 2 | Single | MY2IN(S) |
4 | Single | MY4IN(S) | ||
Bifurcated | MY4ZIN(S) | |||
Models with built-in diode for coil surge absorption (DC coil specification only) |
2 | Single | MY2IN-D2(S) | |
4 | Single | MY4IN-D2(S) | ||
Bifurcated | MY4ZIN-D2(S) | |||
Models with built-in CR circuit for coil surge absorption (AC coil specification only) |
2 | Single | MY4IN-CR(S) | |
4 | Bifurcated | MY4ZIN-CR(S) |
Item | Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) | Must operate voltage (V) |
Must release voltage (V) |
Maximum voltage (V) |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
Rated voltage (V) |
50 Hz | 60 Hz | Armature OFF |
Armature ON |
||||||
AC | 100/110 | 11.7/12.9 | 10/11 | 3,750 | 14.54 | 24.6 | 80% max. *1 |
30% min. *2 |
110% of rated voltage |
Approx. 0.9 to 1.3 (at 60 Hz) |
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
DC | 12 | 75 | 160 | 0.73 | 1.37 | 10% min. *2 |
Approx. 0.9 | |||
24 | 37.7 | 636 | 3.2 | 5.72 | ||||||
48 | 18.8 | 2,560 | 10.6 | 21 |
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value.
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC.
To ensure release, use a value that is lower than the specified value.
Terminal Type | Classification | Number of poles |
Contacts | Without operation indicator |
With operation indicator |
---|---|---|---|---|---|
Plug-in terminals | Standard models | 3 | Single | MY3 | MY3N |
4 | Crossbar bifurcated | MY4Z-CBG | MY4ZN-CBG | ||
PCB terminals | Standard models | 2 | Single | MY2-02 | — |
3 | Single | MY3-02 | — | ||
4 | Single | MY4-02 | — | ||
Bifurcated | MY4Z-02 | — | |||
Case-surface mounting |
Standard models | 2 | Single | MY2F | — |
3 | Single | MY3F | — | ||
4 | Single | MY4F | — | ||
Bifurcated | MY4ZF | — |
Item | Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) | Must operate voltage (V) |
Must release voltage (V) |
Maximum voltage (V) |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
Rated voltage (V) |
50 Hz | 60 Hz | Armature OFF |
Armature ON |
||||||
AC | 12 | 106.5 | 91 | 46 | 0.17 | 0.33 | 80% max. *1 |
30% min. *2 |
110% of rated voltage |
Approx. 0.9 to 1.3 (at 60 Hz) |
24 | 53.8 | 46 | 180 | 0.69 | 1.3 | |||||
100/110 | 11.7/12.9 | 10/11 | 3,750 | 14.54 | 24.6 | |||||
110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
220/240 | 4.8/5.3 | 4.2/4.6 | 18,790 | 83.5 | 136.4 | |||||
DC | 12 | 75 | 160 | 0.73 | 1.37 | 10% min. *2 |
Approx. 0.9 | |||
24 | 36.9 | 650 | 3.2 | 5.72 | ||||||
48 | 18.5 | 2,600 | 10.6 | 21.0 | ||||||
100/110 | 9.1/10 | 11,000 | 45.6 | 86.2 |
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value.
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure
release, use a value that is lower than the specified value.
Contact Ratings
Number of poles (contact configuration) |
2-pole (DPDT) | 3-pole (3PDT) | ||||||
---|---|---|---|---|---|---|---|---|
Contact structure |
Single | Bifurcated | Single | |||||
With latching lever (S) | ||||||||
Load | Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 5 A at 220 VAC 5 A at 24 VDC |
2 A at 220 VAC 2 A at 24 VDC |
5 A at 250 VAC 5 A at 30 VDC |
2 A at 250 VAC 2 A at 30 VDC |
5 A at 220 VAC 5 A at 24 VDC |
2 A at 220 VAC 2 A at 24 VDC |
5 A at 220 VAC 5 A at 24 VDC |
2 A at 220 VAC 2 A at 24 VDC |
Rated carry current*1 |
5 A (10 A*2) | 5 A | 5 A | |||||
Maximum switching voltage |
250 VAC, 125 VDC | 250 VAC, 125 VDC | ||||||
Maximum switching current |
5 A | 10 A | 5 A | 5 A | ||||
Maximum switching power |
1,100 VA 120 W |
440 VA 48 W |
2,500 VA 300 W |
500 VA 60 W |
1,100 VA 120 W |
440 VA 48 W |
1,100 VA 120 W |
440 VA 48 W |
Contact material |
Ag | Au plating + Ag | Ag |
Number of poles (contact configuration) | 4-pole (4PDT) | |||
---|---|---|---|---|
Contact structure | Single | |||
With latching lever (S) | ||||
Load | Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 3 A at 220 VAC 3 A at 24 VDC |
0.8 A at 220 VAC 1.5 A at 24 VDC |
3 A at 250 VAC 3 A at 30 VDC |
0.8 A at 250 VAC 1.5 A at 30 VDC |
Rated carry current*1 | 3 A (5 A*2) | |||
Maximum switching voltage | 250 VAC, 125 VDC | |||
Maximum switching current | 3 A (5 A*2) | |||
Maximum switching power | 660 VA 72 W |
176 VA 36 W |
1,250 VA 150 W |
200 VA 45 W |
Contact material | Au cladding + Ag alloy (Au plating + Ag*3) |
Number of poles (contact configuration) |
4-pole (4PDT) | |||||
---|---|---|---|---|---|---|
Contact structure | Bifurcated | Crossbar bifurcated (CBG) | ||||
With latching lever (S) | ||||||
Load | Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load |
Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 3 A at 220 VAC 3 A at 24 VDC |
0.8 A at 220 VAC 1.5 A at 24 VDC |
3 A at 250 VAC 3 A at 30 VDC |
0.8 A at 250 VAC 1.5 A at 30 VDC |
1 A at 220 VAC 1 A at 24 VDC |
0.3 A at 220 VAC 0.5 A at 24 VDC |
Rated carry current*1 | 3 A (5 A*2) | 1 A | ||||
Maximum switching voltage |
250 VAC, 125 VDC | |||||
Maximum switching current |
3 A (5 A*2) | 1 A | ||||
Maximum switching power |
660 VA 72 W |
176 VA 36 W |
1,250 VA 150 W |
200 VA 45 W |
220 VA 24 W |
66 VA 12 W |
Contact material | Au cladding + Ag alloy (Au plating + Ag*3) | Au cladding + AgPd |
*1.If you use a Socket, do not exceed the rated carry current of the Socket.
*2.Values shown in parentheses are for the MY[](S) model with latching lever.
*3. For MY[]-02 relays with PCB terminals and MY[]F case-surface-mounting relays.
Characteristics
Number of poles (contact configuration) | 2-pole (DPDT) | 3-pole (3PDT) | ||
---|---|---|---|---|
Contact structure | Single | Bifurcated | Single | |
Contact resistance*1 *2 | 50 mΩ max. | |||
Operate time*3 | 20 ms max. | |||
Release time*3 | 20 ms max. | |||
Maximum switching frequency |
Mechanical | 18,000 operations/h | ||
Rated load | 1,800 operations/h | |||
Insulation resistance*4 | 100 MΩ min. | |||
Dielectric strength |
Between coil and contacts | 2,000 VAC, 50/60 Hz for 1 min | ||
Between contacts of different polarity |
||||
Between contacts of the same polarity |
1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance |
Destruction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | ||
Malfunction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |||
Shock resistance |
Destruction | 1,000 m/s2 | ||
Malfunction | 200 m/s2 | |||
Endurance | Mechanical | AC: 50,000,000 operations min. DC: 100,000,000 operations min. (switching frequency: 18,000 operations/h) |
AC: 50,000,000 operations min. DC: 50,000,000 operations min. (switching frequency: 18,000 operations/h) |
AC: 50,000,000 operations min. DC: 100,000,000 operations min. (switching frequency: 18,000 operations/h) |
Electrical*5 | 500,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
200,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
500,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
|
Failure rate P value (reference value)*6 | 1 mA at 5 VDC | 100 μA at 1 VDC | 1 mA at 5 VDC | |
Weight | Approx. 35 g | Approx. 35 g | Approx. 35 g |
Number of poles (contact configuration) | 4-pole (4PDT) | |||
---|---|---|---|---|
Contact structure | Single | Bifurcated | Crossbar bifurcated (CBG) |
|
Contact resistance*1 *2 | 50 mΩ max. | 100 mΩ max. | ||
Operate time*3 | 20 ms max. | |||
Release time*3 | 20 ms max. | |||
Maximum switching frequency |
Mechanical | 18,000 operations/h | ||
Rated load | 1,800 operations/h | |||
Insulation resistance*4 | 100 MΩ min. | |||
Dielectric strength |
Between coil and contacts | 2,000 VAC, 50/60 Hz for 1 min | ||
Between contacts of different polarity |
||||
Between contacts of the same polarity |
1,000 VAC at 50/60 Hz for 1 min | 700 VAC at 50/60 Hz for 1 min |
||
Vibration resistance |
Destruction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | ||
Malfunction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |||
Shock resistance |
Destruction | 1,000 m/s2 | ||
Malfunction | 200 m/s2 | |||
Endurance | Mechanical | AC: 50,000,000 operations min. DC: 100,000,000 operations min. (switching frequency: 18,000 operations/h) |
AC: 20,000,000 operations min. DC: 20,000,000 operations min. (switching frequency: 18,000 operations/h) |
AC: 50,000,000 operations min. DC: 50,000,000 operations min. (switching frequency: 18,000 operations/h) |
Electrical*5 | 200,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
100,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
50,000 operations min. (rated load, switching frequency: 1,800 operations/h) |
|
Failure rate P value (reference value)*6 | 1 mA at 1 VDC | 100 μA at 1 VDC | 100 μA at 1 VDC | |
Weight | Approx. 35 g | Approx. 35 g | Approx. 35 g |
Note: The data shown above are initial values.
*1.Models with latching lever are 100 mΩ maximum.
*2.Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*3.Measurement conditions: With rated operating power applied, not including contact bounce.
*4.Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*5.Ambient temperature condition: 23°C
*6.This value was measured at a switching frequency of 120 operations per minute.
Classification | Standard models | Models with built-in diode for coil surge absorption (-D)/ Models with built-in CR circuit for coil surge absorption (-CR) |
||||||
---|---|---|---|---|---|---|---|---|
Contacts | Single/bifurcated | Crossbar/bifurcated (CBG) |
Single/bifurcated | |||||
Features | Without operation indicator |
With operation indicator | Without operation indicator |
With operation indicator |
Without operation indicator |
With operation indicator | ||
With latching lever |
With latching lever |
|||||||
Ambient operating temperature *1 |
-55 to 70°C |
-55 to 60°C *2 |
-55 to 70°C | -25 to 70°C |
-25 to 60°C |
-55 to 60°C *2 |
-55 to 60°C *2 |
-55 to 70°C |
Ambient operating humidity |
5% to 85% | 5% to 85% |
*1.With no icing or condensation.
*2.This limitation is due to the diode junction temperature and elements used.
Certified Standards
UL certification (File No. E41515)
Model | Standard number |
Category | Listed/ Recognized |
Operating Coil ratings |
No. of poles |
Contact ratings | Certified number of operations |
---|---|---|---|---|---|---|---|
MY2 MY2N MY2IN(S) MY2N-D2 MY2-D2 MY2IN-D2(S) MY2-CR MY2N-CR |
UL508 | NRNT2 | Recognition | 6 to 240 VAC 6 to 125 VDC |
2 | 10 A, 250 VAC (General Use) 10 A, 30 VDC (General Use) 7 A, 240 VAC (General Use) 7 A, 24 VDC (Resistive) 5 A, 240 VAC (General Use) 5 A, 250 VAC (Resistive) 5 A, 30 VDC (Resistive) 3 A, 265 VAC (Resistive) |
6,000 |
1/6 HP, 250 VAC 1/8 HP, 265 VAC 1/10 HP, 120 VAC |
1,000 | ||||||
B300 Pilot Duty (Same polarity) |
6,000 | ||||||
MY2Z MY2ZN MY2-02 MY2F MY2Z-D MY2Z-D2 MY2Z-CR MY2ZN-CR |
UL508 | NRNT2 | Recognition | 6 to 240 VAC 6 to 125 VDC |
2 | 7 A, 240 VAC (General Use) 7 A, 24 VDC (Resistive) 5 A, 240 VAC (General Use) 5 A, 250 VAC (Resistive) 5 A, 30 VDC (Resistive) 3 A, 265 VAC (Resistive) |
6,000 |
1/6 HP, 250 VAC 1/8 HP, 265 VAC 1/10 HP, 120 VAC |
1,000 | ||||||
B300 Pilot Duty (Same polarity) |
6,000 | ||||||
MY3 MY3N MY3-D MY3N-D2 MY3-02 MY3F |
UL508 | NRNT2 | Recognition | 6 to 240 VAC 6 to 125 VDC |
3 | 5 A, 28 VDC (Resistive) 5 A, 240 VAC (General Use) |
6,000 |
1/6 HP, 250 VAC | 1,000 | ||||||
MY4 MY4N MY4IN(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4Z MY4ZN MY4ZIN(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4Z-CR MY4ZN-CR MY4ZIN-CR(S) MY4-02 MY4F MY4Z-02 MY4ZF |
UL508 | NRNT2 | Recognition | 6 to 240 VAC 6 to 125 VDC |
4 | 5 A, 28 VDC (General Use) (Same polarity) 5 A, 240 VAC (General Use) (Same polarity) 5 A, 30 VDC (Resistive) (Same polarity) 5 A, 250 VAC (Resistive) (Same polarity) 0.2 A, 120 VDC (Resistive) (Same polarity) |
6,000 |
1/6 HP, 250 VAC (Same polarity) 1/10 HP, 120 VAC (Same polarity) |
1,000 | ||||||
B300 Pilot Duty (Same polarity) |
6,000 |
CSA certification (File No. LR31928)
Model | Standard number |
Class number |
Operating Coil ratings |
No. of poles |
Contact ratings | Certified number of operations |
---|---|---|---|---|---|---|
MY2 MY2N MY2IN(S) MY2N-D2 MY2-D2 MY2IN-D2(S) MY2-CR MY2N-CR |
C22.2 No.0, No.14 |
6 to 240 VAC 6 to 125 VDC |
2 | 7 A, 240 VAC (Resistive) 7 A, 24 VDC (Resistive) 5 A, 240 VAC (General Use) 5 A, 250 VAC (Resistive) 5 A, 30 VDC (Resistive) |
6,000 | |
1/6 HP, 250 VAC (Same polarity) 1/10 HP, 120 VAC (Same polarity) |
1,000 | |||||
MY2Z MY2ZN MY2-02 MY2F MY2Z-D MY2Z-D2 MY2Z-CR MY2ZN-CR |
C22.2 No.0, No.14 |
6 to 240 VAC 6 to 125 VDC |
2 | 7 A, 240 VAC (General Use) (Same polarity) 7 A, 24 VDC (Resistive) (Same polarity) 5 A, 240 VAC (General Use) (Same polarity) 5 A, 30 VDC (Resistive) 5 A, 250 VAC (Resistive) (Same polarity) 0.2 A, 120 VDC (Resistive) |
6,000 | |
1/6 HP, 250 VAC 1/10 HP, 120 VAC |
1,000 | |||||
MY3 MY3N MY3-D MY3N-D2 MY3-02 MY3F |
C22.2 No.0, No.14 |
6 to 240 VAC 6 to 125 VDC |
3 | 5 A, 28 VDC (Resistive) 5 A, 240 VAC (General Use) 7 A, 240 VAC (General Use) 7 A, 24 VDC (Resistive) |
6,000 | |
1/6 HP, 250 VAC | 1,000 | |||||
MY4 MY4N MY4N(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4-CR MY4N-CR MY4IN-CR(S) MY4Z MY4ZN MY4ZIN(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4Z-C MY4ZN-CR MY4ZIN-CR(S) |
C22.2 No.14 | 3211 07 | 6 to 240 VAC 6 to 125 VDC |
4 | 5 A, 240 VAC (General Use) (Same polarity) 5 A, 28 VDC (General Use) (Same polarity) 5 A, 250 VAC (Resistive) (Same polarity) 5 A, 30 VDC (Resistive) (Same polarity) 0.2 A, 120 VDC (Resistive) (Same polarity) |
6,000 |
1/6 HP, 250 VAC (Same polarity) 1/10 HP, 120 VAC (Same polarity) |
1,000 | |||||
B300 Pilot Duty (Same polarity) | 6,000 | |||||
MY4-02 MY4F MY4Z-02 MY4ZF |
C22.2 No.0, No.14 |
3211 07 | 6 to 240 VAC 6 to 125 VDC |
4 | 7 A, 240 VAC (General Use) (Same polarity) 7 A, 24 VDC (Resistive) (Same polarity) 5 A, 240 VAC (General Use) (Same polarity) 5 A, 30 VDC (Resistive) 5 A, 250 VAC (Resistive) (Same polarity) 0.2 A, 120 VDC (Resistive) |
6,000 |
1/6 HP, 250 VAC 1/10 HP, 120 VAC |
1,000 |
TÜV Rheinland certification (Certification No. R50030059)
Model | Operating Coil ratings | Contact ratings | Certified number of operations |
---|---|---|---|
MY2Z MY2ZN MY2-02 MY2F MY2Z-D MY2Z-D2 MY2Z-CR MY2ZN-CR |
6 to 125 VDC, 6 to 240 VAC |
5 A, 250 VAC (cos φ = 1.0) | 100,000 |
MY3 MY3N MY3-D MY3N-D2 MY3-02 MY3F |
5 A, 250 VAC (cos φ = 1.0) 0.8 A, 250 VAC (cos φ = 0.4) |
||
MY4-02 MY4F MY4Z-02 MY4ZF |
3 A, 120 VAC (cos φ = 1.0) 0.8 A, 250 VAC (cos φ = 0.4) |
CE Marking
Model | EMC Directive | Low Voltage Directive | Machinery Directive | Safety Category |
---|---|---|---|---|
MY2 MY2N MY2IN(S) MY2Z MY2ZN MY2-D MY2N-D2 MY2IN-D2(S) MY2-CR MY2N-CR MY2Z-CR MY2ZN-CR MY2Z-D MY2ZN-D2 MY2F |
Not applicable | Applicable | Not applicable | 1 |
MY3 MY3N MY3-D MY3N-D2 MY3F |
||||
MY4 MY4N MY4IN(S) MY4Z MY4ZN MY4ZIN(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4-CR MY4N-CR MY4Z-CR MY4ZN-CR MY4F MY4ZF |
LR certification (Lloyd’s Register)
Model | File No. | Environmental Category |
Operating Coil ratings |
Contact ratings | Certified number of operations |
---|---|---|---|---|---|
MY2 MY2N MY2IN(S) MY2-D MY2N-D2 MY2IN-D2(S) MY2-CR MY2N-CR |
File No.98/10014 | ENV2,3 | 6 to 240 VAC 6 to 125 VDC |
10 A, 250 VAC (Resistive) 2 A, 250 VAC (PF0.4) 10 A, 30 VDC (Resistive) 2 A, 30 VDC (L/R = 7 ms) |
MY2: 50,000 |
MY2Z MY2ZN MY2Z-D MY2ZN-D2 |
File No.90/10270 | ENV2,3 | 6 to 240 VAC 6 to 125 VDC |
2 A, 30 VDC inductive load 2 A, 200 VAC inductive load |
MY2: 50,000 |
MY4 MY4N MY4IN(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4-CR MY4N-CR MY4IN-CR(S) MY4Z MY4ZN MY4ZIN(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4Z-CR MY4ZN-CR MY4ZIN-CR(S) |
File No.98/10014 | ENV2,3 | 6 to 240 VAC 6 to 125 VDC |
5 A, 250 VAC (Resistive) 0.8 A, 250 VAC (PF0.4) 5 A, 30 VDC (Resistive) 1.5 A, 30 VDC (L/R = 7 ms) |
MY4: 50,000 |
VDE certification
Model | Standard number |
Certification No. | Operating Coil ratings |
Contact ratings | Certified number of operations |
---|---|---|---|---|---|
MY2 MY2N MY2IN(S) MY2-D MY2N-D2 MY2IN-D2(S) MY2-CR MY2N-CR |
EN 61810-1 | 112467UG | 6, 12, 24, 48/50, 100/110, 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC |
10A, 250 VAC (cos φ = 1) 10A, 30 VDC (L/R = 0 ms) |
MY2: 100,000 MY4: 100,000 MY4Z: 50,000 (AC) |
MY4 MY4N MY4IN(S) MY4Z MY4ZN MY4ZIN(S) MY4-D MY4ZN-D2 MY4IN-D2(S) MY4Z-D MY4Z-D2 MY4ZIN-D2(S) MY4-CR MY4N-CR MY4IN-CR(S) MY4Z-CR MY4ZN-CR MY4ZIN-CR(S) |
6, 12, 24, 48/50, 100/110, 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC |
5 A, 250 VAC (cos φ = 1) 5 A, 30 VDC (L/R = 0 ms) |
MYK Miniature Power Latching Relays
Ratings
Operating coil
Rated voltage (V) |
Set coil | Reset coil | Must operate voltage (V) |
Must release voltage (V) |
Maximum voltage (V) |
Power consumption (VA, W) |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated current (mA) |
Coil resistance (Ω) |
Rated current (mA) |
Coil resistance (Ω) |
Set coil | Reset coil | |||||||
50 Hz | 60 Hz | 50 Hz | 60 Hz | |||||||||
AC | 12 | 57 | 56 | 72 | 39 | 38.2 | 130 | 80% max.* |
80% max. |
110% max. of rated voltage |
Approx. 0.6 to 0.9 (at 60 Hz) |
Approx. 0.2 to 0.5 (at 60 Hz) |
24 | 27.4 | 26.4 | 320 | 18.6 | 18.1 | 550 | ||||||
100 | 7.1 | 6.9 | 5,400 | 3.5 | 3.4 | 3,000 | ||||||
DC | 12 | 110 | 110 | 50 | 235 | Approx. 1.3 |
Approx. 0.6 |
|||||
24 | 52 | 470 | 25 | 940 | ||||||||
48 | 27 | 1,800 | 16 | 3,000 |
2. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for AC rated current and ±15% for DC coil resistance.
3. The AC coil resistance is a reference value only.
4. Operating characteristics were measured at a coil temperature of 23°C.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*There is variation between products, but actual values are 80% maximum.
Contact Ratings
Number of poles (contact configuration) | 2-pole (DPDT) | |
---|---|---|
Contact structure | Single | |
Load | Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 3 A at 220 VAC 3 A at 24 VDC |
0.8 A at 220 VAC 1.5 A at 24 VDC |
Rated carry current | 3 A | |
Maximum switching voltage | 250 VAC, 125 VDC | |
Maximum switching current | 3 A | |
Maximum switching power | 660 VA 72 W |
176 VA 36 W |
Contact material | Au plating + Ag |
Characteristics
Contact resistance*1 | 50 mΩ max. | |
---|---|---|
Set | Operate time*2 | AC: 30 ms max., DC: 15 ms max. |
Minimum pulse width | AC: 60 ms, DC: 30 ms | |
Reset | Release time*2 | AC: 30 ms max., DC: 15 ms max. |
Minimum pulse width | AC: 60 ms, DC: 30 ms | |
Maximum switching frequency |
Mechanical | 18,000 operations/h |
Rated load | 1,800 operations/h | |
Insulation resistance*3 | 100 MΩ min. | |
Dielectric strength |
Between coil and contacts Between contacts of different polarity |
1,500 VAC at 50/60 Hz for 1 min |
Between contacts of the same polarity |
1,000 VAC at 50/60 Hz for 1 min | |
Between set/reset coils | ||
Vibration resistance |
Destruction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |
Shock resistance |
Destruction | 1,000 m/s2 |
Malfunction | 200 m/s2 | |
Endurance | Mechanical | 100,000,000 operations min. (switching frequency: 18,000 operations/h) |
Electrical*4 | 200,000 operations min. (at rated load, switching frequency: 1,800 operations/h) |
|
Failure rate P value (reference value)*5 | 1 mA at 1 VDC | |
Ambient operating temperature*6 | -55 to 60°C | |
Ambient operating humidity | 5% to 85% | |
Weight | Approx. 30 g |
Note: The data shown above are initial values.
*1.Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2.Measurement conditions: With rated operating power applied, not including contact bounce.
*3.Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4.Ambient temperature condition: 23°C
*5.This value was measured at a switching frequency of 120 operations per minute.
*6.With no icing or condensation.
MYQ/MYH Miniature Power Sealed Relays
Operating coil
Rated voltage (V) |
Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) | Must operate voltage (V)*1 |
Must release voltage (V)*2 |
Maximum voltage (V) |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
50 Hz | 60 Hz | Armature OFF |
Armature ON |
|||||||
AC | 24 | 53.8 | 46 | 180 | 0.69 | 1.3 | 80% max. |
30% min. |
110% max. of rated voltage |
Approx. 0.9 to 1.3 (at 60 Hz) |
100/110 | 11.7/12.9 | 10/11 | 3,750 | 14.54 | 24.6 | |||||
110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 91.07 | |||||
220/240 | 4.8/5.3 | 4.2/4.6 | 18,790 | 83.5 | 136.4 | |||||
DC | 12 | 75 | 165 | 0.734 | 1.37 | 10% min. |
Approx. 0.9 | |||
24 | 36.9 | 650 | 3.2 | 5.72 | ||||||
48 | 18.5 | 2,600 | 10.6 | 21.0 | ||||||
100/110 | 9.1/10 | 11,000 | 45.6 | 86.0 |
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and coil inductance values are for reference only.
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% maximum. To ensure operation, apply at least 80% of
the rated value.
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure
release, use a value that is lower than the specified value.
Contact Ratings
Plastic Sealed Relays: MYQ
Number of poles (contact configuration) | 4-pole (4PDT) | |
---|---|---|
Contact structure | Single/bifurcated | |
Load | Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 1 A at 220 VAC 1 A at 24 VDC |
0.5 A at 220 VAC 0.5 A at 24 VDC |
Rated carry current | 1 A | |
Maximum switching voltage | 250 VAC 125 VDC |
|
Maximum switching current | 1 A | |
Maximum switching power | 220 VA 24 W |
110 VA 12 W |
Contact material | Au plating + Ag |
Hermetically Sealed Relays: MYH
Number of poles (contact configuration) |
4-pole (4PDT) | |||
---|---|---|---|---|
Contact structure | Single | Bifurcated | ||
Load | Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Rated load | 3 A at 110 VAC 3 A at 24 VDC |
0.8 A at 110 VAC 1.5 A at 24 VDC |
3 A at 110 VAC 3 A at 24 VDC |
0.8 A at 110 VAC 1.5 A at 24 VDC |
Rated carry current | 3 A | |||
Maximum switching voltage | 125 VAC 125 VDC |
|||
Maximum switching current | 3 A | |||
Maximum switching power | 330 VA 72 W |
88 VA 36 W |
330 VA 72 W |
88 VA 36 W |
Contact material | Au plating + Ag |
Characteristics
Model | MYQ | MYH | |
---|---|---|---|
Contact resistance*1 | 50 mΩ max. | ||
Operate time*2 | 20 ms max. | ||
Release time*2 | 20 ms max. | ||
Maximum switching frequency |
Mechanical | 18,000 operations/h | |
Rated load | 1,800 operations/h | ||
Insulation resistance*3 | 100 MΩ min. | ||
Dielectric strength |
Between coil and contacts |
2,000 VAC at 50/60 Hz for 1 min | 1,000 VAC at 50/60 Hz for 1 min |
Between contacts of different polarity |
2,000 VAC at 50/60 Hz for 1 min | 1,000 VAC at 50/60 Hz for 1 min | |
Between contacts of the same polarity |
1,000 VAC at 50/60 Hz for 1 min | 700 VAC at 50/60 Hz for 1 min | |
Vibration resistance |
Destruction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |
Malfunction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | ||
Shock resistance |
Destruction | 1,000 m/s2 | |
Malfunction | 200 m/s2 | ||
Endurance | Mechanical | Single contacts: AC: 50,000,000 operations min., DC: 100,000,000 operations min. Bifurcated contacts: 5,000,000 operations min., DC: 5,000,000 operations min. (switching frequency: 18,000 operations/h) |
Single contacts: 50,000,000 operations min. Bifurcated contacts: 5,000,000 operations min. (switching frequency: 18,000 operations/h) |
Electrical*4 | Single contacts: 200,000 operations min. Bifurcated contacts: 100,000 operations min. (at rated load, switching frequency: 1,800 operations/h) |
Single contacts: 100,000 operations min. Bifurcated contacts: 50,000 operations min. (at rated load, switching frequency: 1,800 operations/h) |
|
Failure rate P Level (reference value)*5 |
Single contacts: 1 mA at 1 VDC Bifurcated contacts: 100 μA at 1 VDC |
Single contacts: 100 μA at 1 VDC Bifurcated contacts: 100 μA at 100 mVDC |
|
Ambient operating temperature*6 | -55 to 60°C | -25 to 60°C | |
Ambient operating humidity | 5% to 85% | ||
Weight | Approx. 35 g | Approx. 50 g |
Note: The data shown above are initial values.
*1.Measurement conditions:1 A at 5 VDC using the voltage drop method.
*2.Measurement conditions:With rated operating power applied, not including contact bounce.
Ambient temperature condition:23°C
*3.Measurement conditions:For 500 VDC applied to the same location as for dielectric strength measurement.
*4.Ambient temperature condition:23°C
*5.This value was measured at a switching frequency of 120 operations per minute.
*6.With no icing or condensation.
Common Options (Order Separately)
Characteristics
Sockets
Socket Accessories
For Front-connecting Sockets
Short Bars
Application | Applicable sockets |
Model | Maximum carry current |
Ambient operating temperature |
Ambient operating humidity |
---|---|---|---|---|---|
Bridging contact terminals (common) |
PYF-08-PU(-L) PYF-14-PU(-L) |
PYDN-7.75-020[] | 20 A | -40 to 70°C | 5% to 85% |
PYDN-7.75-030[] | |||||
PYDN-7.75-040[] | |||||
PYDN-7.75-200[] | |||||
PYFZ-08 |
PYD-025B[] | 20 A (However, 18 A when 70°C) |
-40 to 70°C (with no icing or condensation) |
45% to 85% (with no icing or condensation) |
|
PYD-085B[] | |||||
PYFZ-14 |
PYD-026B[] | ||||
PYD-086B[] | |||||
PYD-020B[] | |||||
PYD-030B[] | |||||
For Coil terminals | PYF-08-PU(-L) PYF-14-PU(-L) |
PYDN-31.0-080[] | 20 A | -40 to 70°C | 5% to 85% |
PYF08S | PYDM-08S[] | 10 A | -40 to 70°C | 5% to 85% | |
PYF14S | PYDM-14S[] | 10 A | -40 to 70°C | 5% to 85% |
Certified Standards
CSA certification (File No. LR031928)
Model | Ratings | Class number | Standard number |
---|---|---|---|
PYF-08-PU | 10 A, 250 V | 3211 07 | CSA C22.2 No14 |
PYF-14-PU | 6 A, 250 V* | ||
PYF08S | 10 A, 250 V | ||
PYF14S | 5 A, 250 V | ||
PYFZ-08(-E) | 10 A, 250 V | ||
PYFZ-14(-E) | 6 A, 250 V | ||
PY[] PYF[]A | 7 A, 250 V |
* When power is supplied to all four poles, use with a total power current that does not exceed 20 A.
UL certification (File No. E87929)
Model | Ratings | Standard number | Category | Listed/Recognized |
---|---|---|---|---|
PYF-08-PU | 10 A, 250 V | UL508 | SWIV2 | Recognition |
PYF-14-PU | 6 A, 250 V* | |||
PYF08S PYF14S |
10 A, 250 V | |||
PYFZ-08(-E) | 10 A, 250 V | |||
PYFZ-14(-E) | 6 A, 250 V | |||
PY[] PYF[]A | 7 A, 250 V |
* When power is supplied to all four poles, use with a total power current that does not exceed 20 A.
TÜV Rheinland certification
Model | Ratings | Standard number | Certification No. |
---|---|---|---|
PYF-08-PU | 10 A, 250 V* | EN 61984 | R50327595 |
PYF-14-PU | 6 A, 250 V | ||
PYFZ-08(-E) | 10 A, 250 V | R50405329 | |
PYFZ-14(-E) | 6 A, 250 V |
*Ratings are for an ambient temperature of 55°C or below. At an ambient temperature of 70°C, the value is 7 A.
VDE certification
Model | Standard number | Certification No. |
---|---|---|
PYF08S | VDE0627 (EN61984) | 40015509 |
PYF14 |
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.
Feel free to contact us for more information :
Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
[email protected]
WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995
Reviews
There are no reviews yet.