Omron

Kindly browse your automation parts that you are looking for on this page! MISEL does offer automation parts from other brands as well such as SIKO, WAGO, AUTONICS, FUJI, and many more. In addition, we also offer support services such as product introduction, installation to our customers who purchase automation parts. To get further details especially about price and availability status of products, don’t be hesitate to contact our marketing team. We are always available to assist you to get your automation needs. Thank You!

Description

• 65 mm depth enables mounting onto control panels with 100 mm depth. • Inputs: 10.2 to 27.6 VDC (DC input) • 7.5-W models provide both ±12-V and ±15-V outputs. • A complete lineup with 10 different models. • UL and CSA approved. • RoHS-compliant

Specifications

Ratings/Characteristics

 
Item DC input
3 W Single output 7.5 W Dual Output 7.5 W
Efficiency (typical) 60% min. 66% min. 64% min.
Input Voltage AC No
DC 10.2 to 27.6 VDC
Current *1 0.6 A max. 1.2 A max.
Output *2 Voltage adjustment range ±5% *3 None *4
Ripple *1 2% (p-p) max.
Input variation influence 0.5% max.
Load variation influence 1.5% max. +V: 1.5% max. -V: 3% max.
Temperature variation influence 0.05%/°C max.
Additional function Overload protection *5 105% min., voltage drop, automatic reset
Other Ambient operating temperature Refer to the derating curve in Engineering Data
Storage temperature -25 to 65°C
Ambient operating humidity 25% to 85% (storage humidity: 20% to 90%)
Dielectric strength 1.5 kVAC for 1 min. (between all input terminals and all output terminals/PE terminals), current off: 10 mA
Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 294 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: green)
Approved standards Refer to List of Certified Models for details.
Weight 150 g max.
*1. A 100% load for rated input voltage.
*2. Output characteristics are measured at the power supply output terminals. *3. If the output voltage adjuster (V.ADJ) is turned, the voltage will increase by more than 50% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. *4. The settings for the output voltage must be within the following range: +V: ±1% of the rated value –V: ±5% of the rated value *5. Refer to Overload Protection on Data Sheet for details.
 
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs. Feel free to contact us for more information : Sales & Marketing Ruko Pengampon Square Blok D-31 Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur [email protected] WhatsApp: +628170006907 T. (031) 355 1715 F. (031) 355 3995