Description
To Improve Reliability of Euipment, Start with Power Supply Selection
How does a Power Supply contribute to stable equipment operation?
Do your power supplies stop due to unexpected external disturbances?
You can increase your equipment operating rates by selecting Power Supplies that have a high resistance to external disturbances.
Designed to Withstand Abnormal Input Voltages Up to 300 VAC*1
In locations where the supply of power is not stable, it is common for abnormal voltages around 300 VAC to be input momentarily. The S8FS withstands this type of momentary abnormal input voltage.
*1. It is not a guaranteed value.
Improved Resistance to Noise of Several Tens of kHz from Inverters
Malfunctions in power supplies can be caused by strong noise of several tens of kHz transmitted from inverters or motors on the same AC line. OMRON measured the noise frequencies and sizes that occurred in actual machines in the past and used them as a standard to improve the noise resistance of the S8FS by harnessing circuit design knowhow to prevent noise from reaching the control section
Lightening Surge Resistance of 1.5 Times*1 the Standard Value
The catalog value conforms to the value specified in IEC 61000-4-5, but it has been confirmed that the ability has a margin of 1.5 times that value.
*1. It is not a guaranteed value.
Design with details in mind provides stable quality and reliability.
average load rate of 80% max., and srandards mounting.
Automatic lines are used in the manufacturing processes to ensure stable Power Supply quality.
OMRON boasts a 38-year track record in Power Supplies.
Specifications
Ratings, Characteristics, and Functions
Power rating | 15 W | |||||
---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | ||
Efficiency * | 115 VAC input | 80% typ. | 84% typ. | 84% typ. | 85% typ. | |
230 VAC input | 82% typ. | 85% typ. | 86% typ. | 87% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||
Current * | 115 VAC input | 0.3 A typ. | ||||
230 VAC input | 0.19 A typ. | |||||
Power factor | — | |||||
Leakage current |
115 VAC input | 0.05 mA | 0.05 mA | 0.05 mA | 0.05 mA | |
230 VAC input | 0.10 mA | 0.10 mA | 0.10 mA | 0.10 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | ||||
230 VAC input | 32 A typ. | |||||
Output | Rated Output Current | 3 A | 1.3 A | 1 A | 0.7 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||
Ripple & Noise voltage * |
100 to 240 VAC input |
30 mVp-p max. | 30 mVp-p max. | 40 mVp-p max. | 30 mVp-p max. | |
Input variation influence * | 0.5% max. | |||||
Load variation influence * | 1.0% max. | |||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | ||||
Startup time * |
115 VAC input | 490 ms typ. | 500 ms typ. | 470 ms typ. | 480 ms typ. | |
230 VAC input | 470 ms typ. | 480 ms typ. | 450 ms typ. | 460 ms typ. | ||
Hold time * | 115 VAC input | 14 ms typ. | 16 ms typ. | 18 ms typ. | 15 ms typ. | |
230 VAC input | 83 ms typ. | 87 ms typ. | 92 ms typ. | 79 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Overheat protection | No | |||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
Remote sensing | No | |||||
Remote control | No | |||||
Output indicator | Yes (LED: Green) | |||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||
Life expectancy * | 10 years min. | |||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||
Weight | 150 g max. | |||||
Cooling fan | No | |||||
Degree of protection | — | |||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
|||||
Marine Standards | No | |||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 25 W | |||||
---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | ||
Efficiency * | 115 VAC input | 80% typ. | 84% typ. | 85% typ. | 86% typ. | |
230 VAC input | 82% typ. | 86% typ. | 88% typ. | 88% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||
Current * | 115 VAC input | 0.49 A typ. | ||||
230 VAC input | 0.3 A typ. | |||||
Power factor | — | |||||
Leakage current |
115 VAC input | 0.10 mA | 0.10 mA | 0.10 mA | 0.10 mA | |
230 VAC input | 0.20 mA | 0.20 mA | 0.20 mA | 0.20 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | ||||
230 VAC input | 32 A typ. | |||||
Output | Rated Output Current | 5 A | 2.1 A | 1.7 A | 1.1 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||
Ripple & Noise voltage * |
100 to 240 VAC input |
20 mVp-p max. | 20 mVp-p max. | 30 mVp-p max. | 40 mVp-p max. | |
Input variation influence * | 0.5% max. | |||||
Load variation influence * | 1.0% max. | |||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | ||||
Startup time * |
115 VAC input | 390 ms typ. | 340 ms typ. | 400 ms typ. | 360 ms typ. | |
230 VAC input | 360 ms typ. | 350 ms typ. | 400 ms typ. | 360 ms typ. | ||
Hold time * | 115 VAC input | 17 ms typ. | 22 ms typ. | 23 ms typ. | 21 ms typ. | |
230 VAC input | 103 ms typ. | 113 ms typ. | 117 ms typ. | 112 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Overheat protection | No | |||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
Remote sensing | No | |||||
Remote control | No | |||||
Output indicator | Yes (LED: Green) | |||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||
Life expectancy * | 10 years min. | |||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||
Weight | 250 g max. | |||||
Cooling fan | No | |||||
Degree of protection | — | |||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
|||||
Marine Standards | No | |||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 35 W | |||||
---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | ||
Efficiency * | 115 VAC input | 81% typ. | 83% typ. | 84% typ. | 87% typ. | |
230 VAC input | 81% typ. | 84% typ. | 84% typ. | 87% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||
Current * | 115 VAC input | 0.66 A typ. | ||||
230 VAC input | 0.41 A typ. | |||||
Power factor | — | |||||
Leakage current |
115 VAC input | 0.15 mA | 0.15 mA | 0.15 mA | 0.15 mA | |
230 VAC input | 0.30 mA | 0.25 mA | 0.25 mA | 0.25 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | ||||
230 VAC input | 32 A typ. | |||||
Output | Rated Output Current | 7 A | 3 A | 2.4 A | 1.5 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||
Ripple & Noise voltage * |
100 to 240 VAC input |
80 mVp-p max. | 90 mVp-p max. | 90 mVp-p max. | 80 mVp-p max. | |
Input variation influence * | 0.5% max. | |||||
Load variation influence * | 1.0% max. | |||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | ||||
Startup time * |
115 VAC input | 750 ms typ. | 750 ms typ. | 760 ms typ. | 770 ms typ. | |
230 VAC input | 700 ms typ. | 690 ms typ. | 710 ms typ. | 720 ms typ. | ||
Hold time * | 115 VAC input | 13 ms typ. | 14 ms typ. | 14 ms typ. | 15 ms typ. | |
230 VAC input | 74 ms typ. | 75 ms typ. | 75 ms typ. | 79 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Overheat protection | No | |||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
Remote sensing | No | |||||
Remote control | No | |||||
Output indicator | Yes (LED: Green) | |||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||
Life expectancy * | 10 years min. | |||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||
Weight | 250 g max. | |||||
Cooling fan | No | |||||
Degree of protection | — | |||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
|||||
Marine Standards | No | |||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 50 W | ||||||
---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | 48 V | ||
Efficiency * | 115 VAC input | 79% typ. | 83% typ. | 84% typ. | 86% typ. | 87% typ. | |
230 VAC input | 80% typ. | 84% typ. | 85% typ. | 86% typ. | 87% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
|||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | ||||||
Current * | 115 VAC input | 0.97 A typ. | |||||
230 VAC input | 0.59 A typ. | ||||||
Power factor | — | ||||||
Leakage current |
115 VAC input | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | |
230 VAC input | 0.60 mA | 0.55 mA | 0.55 mA | 0.55 mA | 0.55 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | |||||
230 VAC input | 32 A typ. | ||||||
Output | Rated Output Current | 10 A | 4.2 A | 3.4 A | 2.2 A | 1.1 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | ||||||
Ripple & Noise voltage * |
100 to 240 VAC input |
80 mVp-p max. |
110 mVp-p max. |
100 mVp-p max. |
100 mVp-p max. |
120 mVp-p max. |
|
Input variation influence * | 0.5% max. | ||||||
Load variation influence * | 1.0% max. | ||||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | |||||
Startup time * |
115 VAC input | 730 ms typ. | 730 ms typ. | 710 ms typ. | 710 ms typ. | 770 ms typ. | |
230 VAC input | 680 ms typ. | 670 ms typ. | 610 ms typ. | 640 ms typ. | 690 ms typ. | ||
Hold time * | 115 VAC input | 12 ms typ. | 14 ms typ. | 14 ms typ. | 14 ms typ. | 14 ms typ. | |
230 VAC input | 71 ms typ. | 77 ms typ. | 78 ms typ. | 77 ms typ. | 80 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | |||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection | No | ||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | ||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | ||||||
Remote sensing | No | ||||||
Remote control | No | ||||||
Output indicator | Yes (LED: Green) | ||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
|||||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | ||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||||
Relia- bility |
MTBF | 135,000 hrs min. | |||||
Life expectancy * | 10 years min. | ||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | |||||
Weight | 300 g max. | ||||||
Cooling fan | No | ||||||
Degree of protection | — | ||||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | |||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||||
EMS | Conforms to EN 61204-3 high severity levels | ||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
||||||
Marine Standards | No | ||||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 75 W | ||||||
---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | 48 V | ||
Efficiency * | 115 VAC input | 75% typ. | 83% typ. | 84% typ. | 87% typ. | 87% typ. | |
230 VAC input | 77% typ. | 83% typ. | 84% typ. | 87% typ. | 87% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
|||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | ||||||
Current * | 115 VAC input | 1.4 A typ. | |||||
230 VAC input | 0.83 A typ. | ||||||
Power factor | — | ||||||
Leakage current |
115 VAC input | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | |
230 VAC input | 0.60 mA | 0.60 mA | 0.60 mA | 0.60 mA | 0.60 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | |||||
230 VAC input | 32 A typ. | ||||||
Output | Rated Output Current | 14 A | 6.2 A | 5 A | 3.2 A | 1.6 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | ||||||
Ripple & Noise voltage * |
100 to 240 VAC input |
80 mVp-p max. |
110 mVp-p max. |
90 mVp-p max. |
110 mVp-p max. |
140 mVp-p max. |
|
Input variation influence * | 0.5% max. | ||||||
Load variation influence * | 1.0% max. | ||||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | |||||
Startup time * |
115 VAC input | 750 ms typ. | 720 ms typ. | 730 ms typ. | 750 ms typ. | 700 ms typ. | |
230 VAC input | 710 ms typ. | 680 ms typ. | 690 ms typ. | 690 ms typ. | 730 ms typ. | ||
Hold time * | 115 VAC input | 12 ms typ. | 13 ms typ. | 13 ms typ. | 14 ms typ. | 15 ms typ. | |
230 VAC input | 75 ms typ. | 74 ms typ. | 74 ms typ. | 76 ms typ. | 78 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | |||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection | No | ||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | ||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | ||||||
Remote sensing | No | ||||||
Remote control | No | ||||||
Output indicator | Yes (LED: Green) | ||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
|||||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | ||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||||
Relia- bility |
MTBF | 135,000 hrs min. | |||||
Life expectancy * | 10 years min. | ||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | |||||
Weight | 350 g max. | ||||||
Cooling fan | No | ||||||
Degree of protection | — | ||||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | |||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||||
EMS | Conforms to EN 61204-3 high severity levels | ||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
||||||
Marine Standards | No | ||||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 100 W | |||||||
---|---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | 36 V | 48 V | ||
Efficiency * | 115 VAC input | 80% typ. | 82% typ. | 83% typ. | 85% typ. | 86% typ. | 87% typ. | |
230 VAC input | 81% typ. | 83% typ. | 84% typ. | 87% typ. | 87% typ. | 88% typ. | ||
Input | Voltage range * | Single phase 85 to 132 VAC, 176 to 264 VAC, 248 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||||
Current * | 115 VAC input | 2 A typ. | ||||||
230 VAC input | 1.1 A typ. | |||||||
Power factor | — | |||||||
Leakage current |
115 VAC input | 0.35 mA | 0.35 mA | 0.35 mA | 0.35 mA | 0.40 mA | 0.40 mA | |
230 VAC input | 0.60 mA | 0.55 mA | 0.60 mA | 0.50 mA | 0.60 mA | 0.60 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 32 A typ. | ||||||
230 VAC input | 32 A typ. | |||||||
Output | Rated Output Current | 20 A | 8.5 A | 7 A | 4.5 A | 2.8 A | 2.3 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||||
Ripple & Noise voltage * |
100 to 120 VAC/200 to 240 VAC input |
70 mVp-p max. |
100 mVp-p max. |
70 mVp-p max. |
120 mVp-p max. |
90 mVp-p max. |
120 mVp-p max. |
|
Input variation influence * | 0.5% max. | |||||||
Load variation influence * | 1.0% max. | |||||||
Temperature variation influence |
100 to 120 VAC/200 to 240 VAC input |
0.03%/°C max. | ||||||
Startup time * |
115 VAC input | 710 ms typ. | 440 ms typ. | 440 ms typ. | 430 ms typ. | 450 ms typ. | 430 ms typ. | |
230 VAC input | 720 ms typ. | 700 ms typ. | 720 ms typ. | 660 ms typ. | 690 ms typ. | 660 ms typ. | ||
Hold time * | 115 VAC input | 23 ms typ. | 37 ms typ. | 36 ms typ. | 34 ms typ. | 36 ms typ. | 34 ms typ. | |
230 VAC input | 29 ms typ. | 40 ms typ. | 39 ms typ. | 39 ms typ. | 41 ms typ. | 38 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||||
Overheat protection | No | |||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||||
Remote sensing | No | |||||||
Remote control | No | |||||||
Output indicator | Yes (LED: Green) | |||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||||
Life expectancy * | 10 years min. | |||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||||
Weight | 400 g max. | |||||||
Cooling fan | No | |||||||
Degree of protection | — | |||||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||||
EMS | Conforms to EN 61204-3 high severity levels | |||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
|||||||
Marine Standards | No | |||||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 150 W | |||||||
---|---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | 36 V | 48 V | ||
Efficiency * | 115 VAC input | 81% typ. | 84% typ. | 85% typ. | 86% typ. | 86% typ. | 87% typ. | |
230 VAC input | 82% typ. | 85% typ. | 86% typ. | 87% typ. | 87% typ. | 88% typ. | ||
Input | Voltage range * | Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||||
Current * | 115 VAC input | 2.8 A typ. | ||||||
230 VAC input | 1.6 A typ. | |||||||
Power factor | — | |||||||
Leakage current |
115 VAC input | 0.50 mA | 0.50 mA | 0.50 mA | 0.50 mA | 0.40 mA | 0.50 mA | |
230 VAC input | 0.75 mA | 0.75 mA | 0.75 mA | 0.70 mA | 0.60 mA | 0.70 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 32 A typ. | ||||||
230 VAC input | 32 A typ. | |||||||
Output | Rated Output Current | 26 A | 12.5 A | 10 A | 6.5 A | 4.3 A | 3.3 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||||
Ripple & Noise voltage * |
100 to 120 VAC/200 to 240 VAC input |
50 mVp-p max. |
90 mVp-p max. |
110 mVp-p max. |
100 mVp-p max. |
200 mVp-p max. |
120 mVp-p max. |
|
Input variation influence * | 0.5% max. | |||||||
Load variation influence * | 1.0% max. | |||||||
Temperature variation influence |
100 to 120 VAC/200 to 240 VAC input |
0.03%/°C max. | ||||||
Startup time * |
115 VAC input | 770 ms typ. | 730 ms typ. | 740 ms typ. | 770 ms typ. | 730 ms typ. | 760 ms typ. | |
230 VAC input | 750 ms typ. | 720 ms typ. | 730 ms typ. | 760 ms typ. | 720 ms typ. | 750 ms typ. | ||
Hold time * | 115 VAC input | 29 ms typ. | 24 ms typ. | 27 ms typ. | 23 ms typ. | 23 ms typ. | 21 ms typ. | |
230 VAC input | 35 ms typ. | 30 ms typ. | 31 ms typ. | 28 ms typ. | 29 ms typ. | 27 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||||
Overheat protection | No | |||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||||
Remote sensing | No | |||||||
Remote control | No | |||||||
Output indicator | Yes (LED: Green) | |||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||||
Life expectancy * | 10 years min. | |||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||||
Weight | 500 g max. | |||||||
Cooling fan | No | |||||||
Degree of protection | — | |||||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||||
EMS | Conforms to EN 61204-3 high severity levels | |||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
|||||||
Marine Standards | No | |||||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 200 W | ||||||
---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 24 V | 36 V | 48 V | ||
Efficiency * | 115 VAC input | 81% typ. | 85% typ. | 88% typ. | 89% typ. | 88% typ. | |
230 VAC input | 81% typ. | 87% typ. | 88% typ. | 90% typ. | 90% typ. | ||
Input | Voltage range * | Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
|||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | ||||||
Current * | 115 VAC input | 4 A typ. | |||||
230 VAC input | 2.3 A typ. | ||||||
Power factor | — | ||||||
Leakage current |
115 VAC input | 0.35 mA | 0.25 mA | 0.40 mA | 0.20 mA | 0.40 mA | |
230 VAC input | 0.60 mA | 0.50 mA | 0.75 mA | 0.45 mA | 0.80 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | |||||
230 VAC input | 32 A typ. | ||||||
Output | Rated Output Current | 40 A | 17 A | 8.8 A | 5.9 A | 4.43 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | ||||||
Ripple & Noise voltage * |
100 to 120 VAC/200 to 240 VAC input |
60 mVp-p max. |
60 mVp-p max. |
110 mVp-p max. |
130 mVp-p max. |
120 mVp-p max. |
|
Input variation influence * | 0.5% max. | ||||||
Load variation influence * | 1.0% max. | ||||||
Temperature variation influence |
100 to 120 VAC/200 to 240 VAC input |
0.03%/°C max. | |||||
Startup time * |
115 VAC input | 620 ms typ. | 630 ms typ. | 580 ms typ. | 630 ms typ. | 620 ms typ. | |
230 VAC input | 600 ms typ. | 610 ms typ. | 550 ms typ. | 600 ms typ. | 600 ms typ. | ||
Hold time * | 115 VAC input | 32 ms typ. | 30 ms typ. | 38 ms typ. | 30 ms typ. | 31 ms typ. | |
230 VAC input | 37 ms typ. | 35 ms typ. | 45 ms typ. | 37 ms typ. | 37 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | |||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection | No | ||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | ||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | ||||||
Remote sensing | No | ||||||
Remote control | No | ||||||
Output indicator | Yes (LED: Green) | ||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 50°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
|||||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | ||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||||
Relia- bility |
MTBF | 135,000 hrs min. | |||||
Life expectancy * | 10 years min. | ||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | |||||
Weight | 700 g max. | ||||||
Cooling fan | No | ||||||
Degree of protection | — | ||||||
Stan- dards |
Harmonic current emissions | — | |||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class A, EN 55011 Class A | |||||
Radiated Emissions |
Conforms to EN 61204-3 Class A, EN 55011 Class A | ||||||
EMS | Conforms to EN 61204-3 high severity levels | ||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
||||||
Marine Standards | No | ||||||
SEMI | No |
* Refer to Conditions of below.
Power rating | 350 W | ||||||
---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 24 V | 36 V | 48 V | ||
Efficiency * | 115 VAC input | 77% typ. | 83% typ. | 86% typ. | 87% typ. | 87% typ. | |
230 VAC input | 78% typ. | 85% typ. | 88% typ. | 88% typ. | 88% typ. | ||
Input | Voltage range * | Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
|||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | ||||||
Current * | 115 VAC input | 6.4 A typ. | |||||
230 VAC input | 3.5 A typ. | ||||||
Power factor | — | ||||||
Leakage current |
115 VAC input | 0.40 mA | 0.40 mA | 0.40 mA | 0.40 mA | 0.40 mA | |
230 VAC input | 0.75 mA | 0.80 mA | 0.75 mA | 0.80 mA | 0.80 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | |||||
230 VAC input | 32 A typ. | ||||||
Output | Rated Output Current | 60 A | 29 A | 14.6 A | 9.7 A | 7.32 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | ||||||
Ripple & Noise voltage * |
100 to 120 VAC/200 to 240 VAC input |
110 mVp-p max. |
130 mVp-p max. |
120 mVp-p max. |
180 mVp-p max. |
180 mVp-p max. |
|
Input variation influence * | 0.5% max. | ||||||
Load variation influence * | 2.0% max. | 1.0% max. | |||||
Temperature variation influence |
100 to 120 VAC/200 to 240 VAC input |
0.03%/°C max. | |||||
Startup time * |
115 VAC input | 610 ms typ. | 620 ms typ. | 580 ms typ. | 610 ms typ. | 610 ms typ. | |
230 VAC input | 570 ms typ. | 590 ms typ. | 560 ms typ. | 590 ms typ. | 590 ms typ. | ||
Hold time * | 115 VAC input | 25 ms typ. | 18 ms typ. | 17 ms typ. | 19 ms typ. | 19 ms typ. | |
230 VAC input | 31 ms typ. | 25 ms typ. | 23 ms typ. | 25 ms typ. | 24 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | |||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection | Yes, power shut off (shut off the input voltage and turn on the input again) (Overheat protection when the cooling fan is in an abnormal condition) |
||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | ||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | ||||||
Remote sensing | No | ||||||
Remote control | No | ||||||
Output indicator | Yes (LED: Green) | ||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
|||||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | ||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||||
Relia- bility |
MTBF | 135,000 hrs min. | |||||
Life expectancy * | 10 years min. | ||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | |||||
Weight | 800 g max. | ||||||
Cooling fan | Yes (ON/OFF control according to internal temperature) | ||||||
Degree of protection | — | ||||||
Stan- dards |
Harmonic current emissions | — | |||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class A, EN 55011 Class A | |||||
Radiated Emissions |
Conforms to EN 61204-3 Class A, EN 55011 Class A | ||||||
EMS | Conforms to EN 61204-3 high severity levels | ||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 Conformed Standards EN: EN 62368-1 OVC II Pol2 EAC (TR CU 004 / 2011, TR CU 020 / 2011) RCM (EN61000-6-4) |
||||||
Marine Standards | No | ||||||
SEMI | No |
* Refer to Conditions of below.
Conditions
Efficiency | The value is given for the rated output voltage and rated output current. | |
---|---|---|
Input | Voltage range | Although some inverters give 50/60 Hz as the output frequency, do not use an inverter output as the power source for the Power Supply. Doing so may result in smoking or burning due to internal temperature increases in the Power Supply. If you connect a UPS to the input, do not connect one with a square wave output. |
Frequency | ||
Current | The value is given for the rated output voltage and rated output current. | |
Inrush current (for a cold start at 25°C) |
The value is given for a cold start at 25°C. Refer to following for details. | |
Output | Voltage adjustment range |
If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by 10% or more over the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. |
Ripple & Noise voltage |
The value is given for the rated output voltage and rated output current. The value is for an ambient operating temperature of 25°C. |
|
Input variation influence |
This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. |
|
Load variation influence |
This is the value when the output current is changed from 0 A to the rated output current while the input voltage is within the allowable input voltage. |
|
Startup time | The value is given for the rated output voltage and rated output current. The value is given for a cold start at 25°C. Refer to following for details. |
|
Hold time | The value is given for the rated output voltage and rated output current. Refer to following for details. |
|
Additional functions |
Overvoltage protection |
Refer to Overvoltage Protection on Data Sheet for information on resetting the input power. |
Reliability | Life expectancy | Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on Data Sheet for details. |
For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.
Feel free to contact us for more information :
Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
[email protected]
WhatsApp: +628170006907
T. (031) 355 1715
Reviews
There are no reviews yet.