S8TS SERIES

SKU: OMRON-PS-S8TS Categories: Omron, Power Supply Omron
  • Description
  • Reviews (0)

Description

• One model covers 30 to 120 W (12-V models).
• One model covers 60 to 240 W (24-V models).
• Easy creation of multi-power supply configurations with different output power supplies connected together (5-V, 12-V, and 24-V models).
• Improve power supply system reliability by creating N+1 redundant systems (12-V and 24-V models).
• RoHS-compliant
• Input conditions: 80 to 370 VDC supported for DC input too (EC Directives and safety standards are not applicable.)
• Operating temperatures to –20°C (24-V models).

 

Specifications

12/24-V Models (Basic Block: S8TS-06024[]/S8TS-03012[])

 

Item Single operation Parallel operation
Efficiency (TYP.) 24-V models: 80% TYP. ; 12-V models: 73% TYP. (with rated input, 100% load)
Input Voltage *1 Ratings: 100 to 240 VAC (Allowable range: 85 to 264 VAC, 80 to 370 VDC *8)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current 100 V input 24-V models: 1.0 A max.
12-V models: 0.7 A max.
24-V models: 1.0 A × (No. of Blocks) max.
12-V models: 0.7 A × (No. of Blocks) max.
200 V input 24-V models: 0.5 A max.
12-V models: 0.4 A max.
24-V models: 0.5 A × (No. of Blocks) max.
12-V models: 0.4 A × (No. of Blocks) max.
Power factor 24-V models: 0.9 min.; 12-V models: 0.8 min. (with rated input, 100% load)
Harmonic current
emissions
Conforms to EN61000-3-2
Leakage
current
100 V input 0.35 mA max. 0.35 mA × (No. of Blocks) max.
240 V input 0.7 mA max. 0.7 mA × (No. of Blocks) max.
Inrush
current
*5
100 V input 17.5 A max. (for a cold start at 25°C) 17.5 A × (No. of Blocks) max. (for a cold
start at 25°C)
200 V input 35 A max. (for a cold start at 25°C) 35 A × (No. of Blocks) max. (for a cold
start at 25°C)
Output
*4
Voltage adjustment
range
24-V models: 22 to 28 V
12-V models: 12 V ±10% (with V.ADJ) *2
Ripple 2% (p-p) max.
Input variation
influence
0.5% max. (with 85 to 264 VAC input, 100% load)
Load variation
influence
2% max. (with rated input, 10% to
100% load)
3% max. (with rated input, 10% to 100% load)
Temperature variation
influence
0.05%/°C max. (with rated input and output)
Startup time 1,000 ms max. (with 100/200 VAC, rated input)
Hold time *5 20 ms min. (with 100/200 VAC, rated input)
Addi-
tional
func-
tions
Overload protection
*5
105% to 140% of rated load current,
voltage drop, automatic reset
100% to 140% of rated load current, voltage
drop, automatic reset
Overvoltage
protection *5 *6
Yes
Parallel operation Yes (Up to 4 Blocks)
N+1 redundant
system
Yes (Up to 5 Blocks)
Series operation Yes
Undervoltage
indicator *5
Yes (color: red)
Undervoltage
detection output *5
Yes (open collector output), 30 VDC max., 50 mA max.
Other Ambient operating
temperature *5
Refer to the derating curve in Engineering Data on Data Sheet (with no icing or
condensation).
Storage temperature -25 to 65°C
Ambient operating
humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 minute (between all inputs and all outputs; detection current: 20 mA)
2.0 kVAC for 1 minute (between all inputs and PE terminal; detection current: 20 mA)
1.0 kVAC for 1 minute (between all outputs and PE terminal; detection current: 20
mA)
Insulation resistance 100 MΩ min. (between all outputs, and all inputs/PE terminal) at 500 VDC
Vibration resistance
*7
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance *7 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Output indicator Yes (color: green)
EMI *8 Conducted
Emission
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A *9
Radiated
Emission
Conforms to EN61204-3 EN55011 Class B *9
EMS *8 Conforms to EN61204-3 High severity levels *9
Approved standards
*8
24V model
UL Listed: UL508 (Listing, Class2 Output: Per UL1310) (See note 3.)
cUL Listed: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223) (See note 3.)
EN: EN62477-112V model
UL Listed: UL508 (Listing)
cUL Listed: CSA C22.2 No.107.1
EN: EN62477-1
Weight 450 g max. 450 g × (No. of Blocks) max.

 

 

*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but
the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. Refer to Data sheet for details on adjusting the output voltage for parallel operation. If set to less than −10%, the
undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do
not exceed the rated output capacity and rated output current respectively. Adjusting V.ADV may cause the output
voltage to exceed the voltage range. When adjusting the output voltage, confirm the actual output voltage from the
Power Supply and be sure that the load is not damaged.
*3. Class 2 approval does not apply to parallel operation.
*4. The output current is specified at power output terminals.
*5. Refer to the Engineering Data on Data sheet for details.
*6. To reset the protection, turn OFF the input power for one minute or longer and then turn it back again.
*7. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply.
*8. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*9. The noise level depends on the wiring method and other factors. Insert one clamp filter (the ZCAT2436-1330A from
TDK) as a noise countermeasure on the input line and ground line combined.

 

5-V Models (Basic Block: S8TS-02505[])

 

Item Single operation
Efficiency (typical) 73% TYP. (with rated input, 100% load)
Input Voltage *1 Ratings: 100 to 240 VAC (Allowable range: 85 to 264 VAC, 80 to 370 VDC *7)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current 100 V input 0.7 A max.
200 V input 0.4 A max.
Power factor 0.8 min. (with rated input, 100% load)
Harmonic current emissions Conforms to EN61000-3-2
Leakage
current
100 V input 0.35 mA max.
240 V input 0.7 mA max.
Inrush
current *5
100 V input 17.5 A max. (for a cold start at 25°C)
200 V input 35 A max. (for a cold start at 25°C)
Output
*3
Voltage adjustment range 5 V ± 10% (with V. ADJ) *2
Ripple 2% (p-p) max.
Input variation influence 0.5% max. (with 85 to 264 VAC input, 100% load)
Temperature variation
influence
0.05%/°C max. (with rated input and output)
Load variation influence 1.5% max. (with rated input, 10% to 100% load)
Startup time *4 1,000 ms max. (with 100/200 VAC, rated input)
Hold time *4 20 ms min. (with 100/200 VAC, rated input)
Addi-
tional
func-
tions
Overload protection *4 105% to 140% of rated load current, voltage drop, automatic reset
Overvoltage protection
*4 *5
Yes
Parallel operation No
N+1 redundant system No
Series operation Yes (with the external diode)
Undervoltage indicator *4 Yes (color: red)
Undervoltage detection
output *4
Yes (open collector output), 30 VDC max., 50 mA max.
Other Ambient operating
temperature *4
Refer to the derating curve in Engineering Data on Data Sheet.
Storage temperature -25 to 65°C (with no icing or condensation)
Ambient operating humidity 25% to 85%, Storage: 25% to 90%
Dielectric strength 3.0 kVAC, 50/60 Hz for 1 minute (between all inputs and all outputs; detection
current: 20 mA)
2.0 kVAC, 50/60 Hz for 1 minute (between all inputs and PE terminal; detection
current: 20 mA)
1.0 kVAC for 1 minute (between all outputs and PE terminal; detection current:
20 mA)
Insulation resistance 100 MΩ min. (between all outputs and inputs/PE terminal) at 500 VDC
Vibration resistance *6 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance *6 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Output indicator Yes (color: green)
EMI *7 Conducted
Emission
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
Radiated
Emission
Conforms to EN61204-3 EN55011 Class B
EMS *7 Conforms to EN61204-3 High severity levels
Approved standards *7 UL Listed: UL508 (Listing)
UL UR: UL60950-1 (Recognition)
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No.60950-1
EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805 Teil1)
Weight 450 g max.

 

*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. If set to less than −10%, the undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current respectively. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 10% of the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*3. The output current is specified at power output terminals.
*4. Refer to the Engineering Data on Data sheet for details.
*5. To reset the protection, turn OFF the input power for one minute or longer and then turn it back again.
*6. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply.
*7. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).

 

For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs.

Feel free to contact us for more information :

Sales & Marketing
Ruko Pengampon Square Blok D-31
Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur
misel.cs@miselsby.com
WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995

Reviews

There are no reviews yet.

Be the first to review “S8TS SERIES” Cancel reply

You must be logged in to post a review.

Related products

  • ZFV SERIES

    Read more
  • E5CN-HT SERIES

    Read more
  • E5AC-T SERIES

    Read more
  • E5CN-H

    Read more

Recent Post

  • Awas! 5 Mitos tentang CoBot Ini Dipastikan Salah
  • Inilah Definisi, Fungsi dan Keuntungan Collaborative Robot (CoBot)
  • Yuk, Mengenal Lebih Lanjut tentang Servo System
  • Berikut Jenis dan Fungsi Proximity Sensor yang Harus Kamu Ketahui!
  • Apa itu Servo Motor? Kenali Komponen dan Fungsi Servo Motor?

Jasa Industrial Automation

PT Mitrainti Sejahtera Eletrindo merupakan perusahaan penyedia industrial automation yang telah dipercaya sebagai distributor berbagai merek industrial automation seperti Omron, Delta, Apex Dynamics, Mitsubishi Electric, Siko, dan AB Mark.

Konsultasikan kebutuhan industrial automation anda kepada kami. Silahkan hubungi kami.

Untuk mengetahui perusahaan kami lebih lagi, silahkan melihat profil perusahaan

Address

Ruko Pengampon Square Blok D-31
Jl. Semut Baru,
Kel. Bongkaran, Kec. Pabean Cantian
Surabaya – Jawa Timur

Phone

WhatsApp: +628170006907
T. (031) 355 1715
F. (031) 355 3995

Email

misel.cs@miselsby.com

PRODUCT

  • Omron
  • Delta Products
  • Apex
  • Mitsubishi
  • Siko
  • JAKA

Latest Posts

  • Awas! 5 Mitos tentang CoBot Ini Dipastikan Salah
  • Inilah Definisi, Fungsi dan Keuntungan Collaborative Robot (CoBot)
  • Yuk, Mengenal Lebih Lanjut tentang Servo System
  • Berikut Jenis dan Fungsi Proximity Sensor yang Harus Kamu Ketahui!

Service and Solution

  • SCADA Systems
  • PLC Programming
  • Inverter Systems
  • Servo Systems
  • Panel Maker
  • Industrial Robotics
  • System Integrator
  • Industrial Automation System

Industrial Robotics

  • AGV Warehouse Automation
  • Parallel Robots
  • Robot Arms
  • SCARA Robots

BLOG

Open Hours

Mon – Fri


8am – 5pm
Sat – Sun


Closed

Contact Us

  • Contact Us
  • Make an Appointment
  • Apply Career

Other Pages

  • Inverter Systems Explanation
  • Apa itu HMI (Human Machine Interface)?
  • PLC Programming Service
  • Delta PLC Programming
  • Mitsubishi PLC Programming
  • PLC Programming FAQs
© PT Mitrainti Sejahtera Eletrindo - Authorized Distributor of OMRON, Delta, Apex, Mitsubshi, Siko, and Weiss.