Omron

Kindly browse your automation parts that you are looking for on this page! MISEL does offer automation parts from other brands as well such as SIKO, WAGO, AUTONICS, FUJI, and many more. In addition, we also offer support services such as product introduction, installation to our customers who purchase automation parts. To get further details especially about price and availability status of products, don’t be hesitate to contact our marketing team. We are always available to assist you to get your automation needs. Thank You!

Description

For More Compact Control Panels

New Value For Control Panels

Control Panels: The Heart of Manufacturing Sites. Evolution in control panels results in large evolution in production facilities. And if control panel design, control panel manufacturing processes, and human interaction with them are innovated, control panel manufacturing becomes simpler and takes a leap forward. OMRON will continue to achieve a control panel evolution and process innovation through many undertakings starting with the shared Value Design for Panel *1 concept for the specifications of products used in control panels.
*1 Value Design for Panel
Our shared Value Design for Panel (herein after referred to as "Value Design") concept for the specifications of products used in control panels will create new value to our customer’s control panels. Combining multiple products that share the Value Design concept will further increase the value provided to control panels.

Specifications

Ratings, Characteristics, and Functions

 
Power rating 30 W 60 W 120 W
Output voltagec (DC) 24 V 24 V 24 V
Efficiency 115 VAC input *1 87% typ. 87% typ. 90% typ.
230 VAC input *1 86% typ. 89% typ. 92% typ.
Input Voltage range *2 Single-phase, 85 to 264 VAC, 90 to 350 VDC *12, 265 to 300 VAC (1 second)
Frequency *2 50/60 Hz (47 to 450 Hz) 50/60 Hz (47 to 63 Hz)
Input current 115 VAC input *1 0.58A typ. 1.1 A typ. 1.2 A typ.
230 VAC input *1 0.36A typ. 0.66 A typ. 0.63 A typ.
Power factor *1 --- 0.9 min.
Leakage current *3 115 VAC input 0.5 mA max.
230 VAC input 1 mA max.
Inrush current *4 (for a cold start at 25°C) 115 VAC input 16 A typ.
230 VAC input 32 A typ.
Output Rated output current 1.3 A 2.5 A 5 A
Rated output electric power 31.2 W 60 W 120 W
Maximum boost current 1.56 A 3 A 6 A
Voltage adjustment range *5 21.6 to 28 V (with V.DJ)
Ripple & Noise voltage *6 100 to 240 VAC input *1 190 mVp-p max. at 20 MHz of bandwidth 190 mVp-p max. at 20 MHz of bandwidth 110 mVp-p max. at 20 MHz of bandwidth
Input variation influence *7 0.5% max.
Load variation influence *8 1.5% max.
Temperature variation influence 115 to 230 VAC input 0.05%/°C max.
Start up time *4 115 VAC input *1 1000 ms max. 1000 ms max. 1000 ms max.
230 VAC input *1 1000 ms max. 1000 ms max. 1000 ms max.
Hold time *6 115 VAC input *1 30 ms typ. 20 ms typ. 45 ms typ.
230 VAC input *1 140 ms typ. 95 ms typ. 45 ms typ.
Additional functions Overload protection Yes, automatic reset
Overvoltage protection *9 Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
Series operation Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation Yes (For up to two Power Supplies), Refer to Parallel Operation on catalog for details.
Output indicator Yes (LED: Green)
Low-voltage detection output No
Insulation Withstand voltage 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 10 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 10 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA
Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/ PE terminals) at 500 VDC
Environ- ment Ambient operating temperature *10 -40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing)
Storage temperature -40 to 85°C (with no condensation or icing)
Ambient operating humidity 95% RH max. (Storage humidity: 95% RH max.)
Vibration resistance 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability MTBF 135,000 hrs min. (Refer to Data Sheet Reference Value)
Life expectancy *11 10 years min.
Con- struction Weight 250 g max. 250 g max. 400 g max.
Cooling fan No
Degree of protection IP20 by EN/IEC 60529
Standards Harmonic current emissions Conforms to EN 61000-3-2
EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS Conforms to EN 61204-3 high severity levels
Safety standards UL Listing: UL 508 (For 30 W and 60 W only Class2 Output: Per UL 1310) cUL: CSA C22.2 No107.1 (For 30 W and 60 W only Class2 Output: Per CSA C22.2 No.223) UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2 cUR: CSA C22.2 No. 62368-1 OVCII (≤ 3000 m) Pol2 EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2, EN 62368-1 OVCII (≤ 3000 m) Pol2 EAC (TR CU 004/2011, TR CU 020/2011) RCM (EN61000-6-4) PELV (EN/IEC 60204-1) *12 EN/IEC 61558-2-16:2009+A1:2013 *12 BIS: IS 13252 (Part1) *12
Marine Standards *12 Lloyd’s register (Except 30 W)
SEMI Conforms to F47-0706 (200 to 240 VAC input)
 
 
Power rating 240 W 480 W
Output voltagec (DC) 24 V 24 V
Efficiency 115 VAC input *1 91% typ. 91% typ.
230 VAC input *1 93% typ. 93% typ.
Input Voltage range *2 Single-phase, 85 to 264 VAC, 90 to 350 VDC *12, 265 to 300 VAC (1 second)
Frequency *2 50/60 Hz (47 to 63 Hz)
Input current 115 VAC input *1 2.4 A typ. 4.6 A typ.
230 VAC input *1 1.3 A typ. 2.3 A typ.
Power factor *1 0.9 min. 0.9 min.
Leakage current *3 115 VAC input 0.5 mA max.
230 VAC input 1 mA max.
Inrush current *4 (for a cold start at 25°C) 115 VAC input 16 A typ.
230 VAC input 32 A typ.
Output Rated output current 10 A 20 A
Rated output electric power 240 W 480 W
Maximum boost current 15 A 30 A
Voltage adjustment range *5 21.6 to 28 V (with V.ADJ)
Ripple & Noise voltage *6 100 to 240 VAC input *1 100 mVp-p max. at 20 MHz of bandwidth 130 mVp-p max. at 20 MHz of bandwidth
Input variation influence *7 0.5% max.
Load variation influence *8 1.5% max.
Temperature variation influence 115 to 230 VAC input 0.05%/°C max.
Start up time *4 115 VAC input *1 1000 ms max. 1000 ms max.
230 VAC input *1 1000 ms max. 1000 ms max.
Hold time *6 115 VAC input *1 35 ms typ. 30 ms typ.
230 VAC input *1 35 ms typ. 30 ms typ.
Additional functions Overload protection Yes, automatic reset
Overvoltage protection *9 Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
Series operation Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation Yes (For up to two Power Supplies), Refer to Parallel Operation on catalog for details.
Output indicator Yes (LED: Green)
Low-voltage detection output Yes (Photoswitch output: 30 VDC max., 50 mA max.)
Insulation Withstand voltage 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA
500 VAC for 1 min (between all output terminals and all low-voltage detection output terminals), current cutoff 10 mA
Insulation resistance 100 MΩ min. (between all output terminals/all low-voltage detection output terminals and all input terminals/PE terminals) at 500 VDC
Environ- ment Ambient operating temperature *10 -40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing)
Storage temperature -40 to 85°C (with no condensation or icing)
Ambient operating humidity 95% RH max. (Storage humidity: 95% RH max.)
Vibration resistance 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability MTBF 135,000 hrs min. (Refer to Data Sheet Reference Value)
Life expectancy *11 10 years min.
Con- struction Weight 700 g max. 1150 g max.
Cooling fan No
Degree of protection IP20 by EN/IEC 60529
Standards Harmonic current emissions Conforms to EN 61000-3-2
EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS Conforms to EN 61204-3 high severity levels
Safety standards UL Listing: UL 508 cUL: CSA C22.2 No107.1 UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2 cUR: CSA C22.2 No.62368-1 OVCII (≤ 3000 m) Pol2 EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2, EN 62368-1 OVCII (≤ 3000 m) Pol2 PELV (EN/IEC 60204-1) *12 EN/IEC 61558-2-16:2009+A1:2013 *12 BIS: IS 13252 (Part1) *12
Marine Standards *12 Lloyd's register
SEMI Conforms to F47-0706 (200 to 240 VAC input)
*1. The value is when both rated output voltage and rated output current are satisfied. *2. Do not use an inverter output for the product. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the product may result in ignition or burning. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or burning. *3. The value for the leakage current is determined according to the Electrical Appliances and Material Safety Act. *4. Refer to Inrush Current, Startup Time, Output Hold Time on Catalog for details. *5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 28 V min of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the product and be sure that the load is not damaged. *6. A characteristic when the ambient operating temperature of 25°C. *7. This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. *8. 100 to 240 VAC input, in the range of 0 A to the rated output current. *9. Refer to Overvoltage Protection on Catalog for the time when input voltage shuts off and input turns on again. *10.At -40 to -25°C, time will be required before the rated output voltage is output after the input voltage is input. Also, the ripple noise value may exceed the value shown in the above table. *11.Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on Catalog for details. *12.Refer to Standard Compliance, below.

Standard Compliance

• EN/IEC 61558-2-16 The S8VK-S was designed based on EN/IEC 61558-2-16. Currently, IEC 61558-2-17 has been replaced by IEC 61558-2-16. When certification was received for EN/IEC 60204-1 (Machinery Safety), it was necessary to go through a control transformer to the control circuits. However, a control transformer is not always necessary for product that have been certified for the safety standard for OVCIII or for product that use a transformer that conforms to EN/IEC 61558-2-16. • Safety Standards for a DC Input The following safety standards are applicable for when a DC input is used: UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN 50178, EN 62368-1 and Lloyd's. Safety standard compliance is achievable by connecting a UL-certified fuse as specified below. Select an external fuse that satisfies the following conditions: S8VK-S03024: 350 VDC min., 6 A S8VK-S06024: 350 VDC min., 6 A S8VK-S12024: 350 VDC min., 8 A S8VK-S24024: 350 VDC min., 8 A S8VK-S48024: 350 VDC min., 12 A • Conformance to Marine Standards Noise filter “FN2080-10-06” manufactured by SCHAFFNER Corporation. or equivalent should be connected to the Input terminals of S8VK-S series (Except 60 W). End Plate (PFP-M) to both sides of the Power Supply to hold the Power Supply in place. Install clamp filters (“ZCAT2035-0930” manufactured by TDK) on the cables connected to the input and output terminals for 240- and 480-W models. • To comply with PELV output requirements for EN/IEC 60204-1, ground the negative side of the output (-V) to a protective earth (PE). • Only 60 W, 120 W, 240 W, and 480 W models are compliant with BIS (IS 13252 (Part 1)).
  For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs. Feel free to contact us for more information : Sales & Marketing Ruko Pengampon Square Blok D-31 Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur [email protected] WhatsApp: +628170006907 T. (031) 355 1715 F. (031) 355 3995