Kindly browse your automation parts that you are looking for on this page! MISEL does offer automation parts from other brands as well such as SIKO, WAGO, AUTONICS, FUJI, and many more. In addition, we also offer support services such as product introduction, installation to our customers who purchase automation parts. To get further details especially about price and availability status of products, don’t be hesitate to contact our marketing team. We are always available to assist you to get your automation needs. Thank You!

Description

New undervoltage alarm function assists in determining causes of errors (S8VM-[][][]24A[]/P[] only).
Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).
Broad range of possibilities with 8 capacities and 29 models to choose from.
RoHS-compliant
New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W models).
Finger protection prevents electric shock.
DIN Rail mounting.
Safety standards: UL508/60950-1, CSA C22.2 No. 14/No. 60950-1, EN50178, EN60950-1 (The 300-, 600-, and 1,500-W models will not conform to safety standards if the customer replaces the fan.)
Conforms to SEMI F47-0200 (when 200-V input is used).
Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).

Specification

Ratings/Characteristics

 
Power rating 15 W 30 W 50 W 100 W 150 W
Efficiency 5-V models 75% min. 75% min. 80% min. 81% min. 81% min.
12-V models 78% min. 79% min. 79% min. 81% min. 81% min.
15-V models 78% min. 79% min. 79% min. 81% min. 81% min.
24-V models 80% min. 81% min. 80% min. 82% min. 83% min.
Input Voltage *1 100 to 240 VAC (85 to 265 VAC)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current 100-V input 0.5 A max. 0.9 A max. 0.8 A max. 1.4 A max. 2.0 A max.
200-V input 0.25 A max. 0.45 A max. 0.4 A max. 0.7 A max. 1.0 A max.
Power factor 100-V input --- 0.98 min.
200-V input --- 0.94 min.
Harmonic current emissions --- Conforms to EN 61000-3-2
Leakage current 100-V input 0.4 mA max. (at rated output)
200-V input 0.75 mA max. (at rated output)
Inrush current *2 100-V input 17.5 A max. (for cold start at 25 °C)
200-V input 35 A max. (for cold start at 25 °C)
Output Voltage adjustment range *3 -20% to 20% (with V. ADJ) (S8VM-[][][]24A[]/P[]: -10% to 20%)
Ripple 3.2% (p-p) max. (5 V), 1.5% (p-p) max. (12 V), 1.2% (p-p) max. (15 V), 1.0% (p-p) max. (24 V), (at rated input/output voltage) 3.2% (p-p) max. (5 V), 1.5% (p-p) max. (12 V), 1.2% (p-p) max. (15 V), 0.75% (p-p) max. (24 V), (at rated input/output voltage)
Input variation influence 0.4% max. (at 85 to 265 VAC input, 100%)
Load variation influence (rated input voltage) 0.8% max. (with rated input, 0 to 100% load)
Temperature variation influence 0.02%/°C max.
Startup time *2 1,100 ms max. (at rated input/output voltage) 800 ms max. (at rated input/output voltage)
Hold time *2 20 ms typ. (15 ms min.) (at rated input/output voltage)
Additional functions Overload protection *2 105% to 160% of rated load current, voltage drop, intermittent, automatic reset 105% to 160% of rated load current, voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), automatic reset
Overvoltage protection *2 Yes *4
Undervoltage alarm indication Yes (color: Yellow (DC LOW1), red (DC LOW2)) (S8VM-[][][]24A[]/P[] only)
Undervoltage alarm output No Yes (S8VM-[][][]24A[]/P[] only) (Transistor output), 30 VDC max., 50 mA max. *8
Series operation Yes for up to 2 Power Supplies (with external diode)
Parallel operation No (However, backup operation is possible. An external diode is required.)
Remote sensing function No Yes
Other Ambient operating temperature Refer to the derating curve in See Engineering Data on Data Sheet (15-W, 30-W, 50-W, 100-W, 150-W Models). (with no icing or condensation) *2
Storage temperature -25 to 65°C
Ambient operating humidity 30% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE/FG terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and PE/FG terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs (except the detection output terminals) and detection output terminals; detection current: 20 mA) (S8VM- [][][]24A[]/P[] only)
Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE/FG terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: Green)
EMI Conducted Emission Conforms to EN55011 Group1 Class B and based on FCC Class B *5
Radiated Emission Conforms to EN55011 Group1 Class B *6
EMS Conforms to EN61204-3 High severity levels
Approved standards UL UL508 (Listing), UL60950-1
cUL CSA C22.2 No.14
cUR CSA No. 60950-1
EN/TÜV EN50178, EN60950-1 SELV (EN60950-1) According to VDE0160/P100
SEMI SEMI F47-0200 (200 VAC input)
Weight *7 180 g max. 220 g max. 290 g max. 460 g max. 530 g max.
 
 
*1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. Refer to Engineering Data (15-W, 30-W, 50-W, 100-W, 150-W Models) on Catalog for details. *3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. *4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. *5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 15-W models, insert a clamp filter (ZCAT2436-1330 by TDK: 50 Ω min. [50 to 500 MHz], or the equivalent) in the output wire to reduce noise. *6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 150-W models, insert a clamp filter (ZCAT2017-0930 by TDK: 35 Ω min. [50 to 500 MHz], or the equivalent) in the input wire to reduce noise. *7. The weight indicated is for bottom mounting, open-frame models. *8. A[]: Sinking type (NPN) P[]: Sourcing type (PNP)
 
 
Power rating 300 W 600 W 1,500 W
Efficiency 5-V models 77% min. 77% min. ---
12-V models 78% min. 79% min. ---
15-V models 79% min. 80% min. ---
24-V models 81% min. 81% min. 82% min.
Input Voltage *1 100 to 240 VAC (85 to 265 VAC) 100 to 240 VAC (85 to 265 VAC)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current 100-V input 4.0 A max. (5 V) 4.3 A max. (12 V, 15 V, and 24 V) 8.0 A max. (5 V) 8.3 A max. (12 V, 15 V, and 24 V) 20.0 A max.
200-V input 2.0 A max. (5 V) 2.2 A max. (12 V, 15 V, and 24 V) 4.0 A max. (5 V) 4.2 A max. (12 V, 15 V, and 24 V) 11.0 A max.
Power factor 100-V input 0.98 min. 0.97 min.
200-V input 0.94 min. 0.93 min.
Harmonic current emissions Conforms to EN61000-3-2
Leakage current 100-V input 0.4 mA max. 1.5 mA max.
200-V input 0.75 mA max. 1.5 mA max.
Inrush current *2 100-V input 20 A max. (for cold start at 25 °C)
200-V input 40 A max. (for cold start at 25 °C)
Output Voltage adjustment range *3 -20% to 20% (with V. ADJ)
Ripple 3.8% (p-p) max. (5 V), 2.0% (p-p) max. (12 V), 2.0% (p-p) max. (15 V), 1.25% (p-p) max. (24 V), (at rated input/output voltage) 1.25% (p-p) max. *7, (at rated input/output voltage)
Input variation influence 0.4% max. (at 85 to 265 VAC input, 100%)
Load variation influence (rated input voltage) 0.6% max. (with rated input, 0 to 100% load)
Temperature variation influence 0.02%/°C max.
Startup time *2 1,000 ms max. (at rated input/output voltage)
Hold time *2 20 ms typ. (15 ms min.) (at rated input/output voltage)
Additional functions Overload protection *2 105% to 160% of rated load current (5 V, 12 V, and 15 V), 120% to 160% of rated load current (S8VM-30024C), 115% to 160% of rated load current (S8VM- 60024C), voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), automatic reset 105% to 160% of rated load current (100 VAC), 155% to 200% of rated load current (200 VAC), voltage drop, automatic reset (Turns OFF when continuous for 5 s min.) *4
Overvoltage protection *2 Yes *4
Overheat protection *2 Yes *4
Undervoltage alarm indication No
Undervoltage alarm output No
Power failure alarm indication Yes (color: Red)
Power failure alarm output Yes (Transistor output), 30 VDC max., 50 mA max.
Series operation Yes for up to 2 Power Supplies (with external diode)
Parallel operation Yes (up to 2 units)
Remote sensing function Yes
Remote control function Yes
Other Ambient operating temperature Refer to the derating curve in See Engineering Data on Data Sheet (300-W, 600-W, 1,500-W Models). (with no icing or condensation) *2
Storage temperature -25 to 65°C
Ambient operating humidity 30% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and PE terminals; detection current: 100 mA) 100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20 mA) 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and FG terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and FG terminals; detection current: 300 mA) 100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20 mA)
Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC 100 MΩ min. (between all outputs and all inputs, FG terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions 10 to 55 Hz, 0.15-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: Green)
EMI Conducted Emission Conforms to EN55011 Group1 Class B and based on FCC Class B *5 Conforms to EN55011 Group1 Class A and based on FCC Class A *6
Radiated Emission Conforms to EN55011 Group1 Class B *5 Conforms to EN55011 Group1 Class A *6
EMS Conforms to EN61204-3 High severity levels
Approved standards *8 UL UL508 (Recognition) (5 V, 12 V, and 15 V) UL508 (Listing) (24 V), UL60950-1 UL508, UL60950-1
cUR CSA C22.2 No.14 (24 V)
cUR CSA No. 60950-1 CSA C22.2 No.14, CSA No. 60950-1
EN/TÜV EN50178, EN60950-1 SELVE (EN60950-1) EN50178, EN60950-1 SELVE (EN60950-1)
SEMI SEMI F47-0200 (200-VAC input)
Weight 1,100 g max. 1,700 g max. 3,800 g max.
 
*1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. Refer to Engineering Data (300-W, 600-W, 1,500-W Models) on Catalog for details. *3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. *4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. Alternatively, turn OFF the remote control signal and then turn it back ON again. *5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 600-W models, insert a clamp filter (ZCAT3035-1330 by TDK: 100 Ω min. [50 to 500 MHz], or the equivalent) in the input wire, and ring core (HF60T38X14X22 by TDK: 16 Ω typ. [1 MHz], 46 Ω typ. [10 MHz], or the equivalent) in the output wire to reduce noise *6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class A when the aluminum plate is laid under the Power Supply (1,500-W models). *7. The measuring method conforms to JEITA standard RC-9131A. Refer to Ripple under Safety Precautions on Catalog. *8. The Power Supply will not conform to safety standards if the customer replaces the fan.
    For over 25 years, PT. Mitrainti Sejahtera Eletrindo (MISEL) has developed automation system solutions to assist our customers in achieving high efficiency and effectiveness in their manufacturing process. We become a trusted partner for local and global companies in diverse industries such as consumer products, tobacco industry, packaging companies, foods and beverages, pharmaceutical, industrial manufacturing, etc. With adequate experiences in automation industry, we are your first and best choice to support your automation needs. Feel free to contact us for more information : Sales & Marketing Ruko Pengampon Square Blok D-31 Jl. Semut Baru, Kel. Bongkaran, Kec. Pabean Cantian Kota Surabaya – Jawa Timur [email protected] WhatsApp: +628170006907 T. (031) 355 1715 F. (031) 355 3995